3.0 Application Notes

3.1 FAN CONTROL DUTY CYCLE VS. REGISTER SETTINGS AND FREQUENCY

PWM

Freq

4D

[4:0]

Step

Resolution,

%

PWM

Value

4D [5:0]

for 100%

PWM

Value

4C [5:0] for

about 75%

PWM

Value

4C [5:0]

for 50%

PWM

Freq at

360 kHz

Internal

Clock, kHz

PWM

Freq at

1.4 kHz

Internal

Clock, Hz

Actual Duty

Cycle, % When

75% is Selected

0

Address 0 is mapped to Address 1

1

50

2

1

1

180.0

703.1

50.0

2

25

4

3

2

90.00

351.6

75.0

3

16.7

6

5

3

60.00

234.4

83.3

4

12.5

8

6

4

45.00

175.8

75.0

5

10.0

10

8

5

36.00

140.6

80.0

6

8.33

12

9

6

30.00

117.2

75.0

7

7.14

14

11

7

25.71

100.4

78.6

8

6.25

16

12

8

22.50

87.9

75.0

9

5.56

18

14

9

20.00

78.1

77.8

10

5.00

20

15

10

18.00

70.3

75.0

11

4.54

22

17

11

16.36

63.9

77.27

12

4.16

24

18

12

15.00

58.6

75.00

13

3.85

26

20

13

13.85

54.1

76.92

14

3.57

28

21

14

12.86

50.2

75.00

15

3.33

30

23

15

12.00

46.9

76.67

16

3.13

32

24

16

11.25

43.9

75.00

17

2.94

34

26

17

10.59

41.4

76.47

18

2.78

36

27

18

10.00

39.1

75.00

19

2.63

38

29

19

9.47

37.0

76.32

20

2.50

40

30

20

9.00

35.2

75.00

21

2.38

42

32

21

8.57

33.5

76.19

22

2.27

44

33

22

8.18

32.0

75.00

23

2.17

46

35

23

7.82

30.6

76.09

24

2.08

48

36

24

7.50

29.3

75.00

25

2.00

50

38

25

7.20

28.1

76.00

26

1.92

52

39

26

6.92

27.0

75.00

27

1.85

54

41

27

6.67

26.0

75.93

28

1.79

56

42

28

6.42

25.1

75.00

29

1.72

58

44

29

6.21

24.2

75.86

30

1.67

60

45

30

6.00

23.4

75.00

31

1.61

62

47

31

5.81

22.7

75.81

3.1.1 Computing Duty Cycles for a Given Frequency

Select a PWM Frequency from the first column correspond-
ing to the desired actual frequency in columns 6 or 7. Note
the PWM Value for 100% Duty Cycle.

Find the Duty Cycle by taking the PWM Value of Register 4C
and computing:

Example: For a PWM Frequency of 24, a PWM Value at
100% = 48 and PWM Value actual = 28, then the Duty Cycle
is (28/48) x 100% = 58.3%.