MAX1519/MAX1545

Dual-Phase, Quick-PWM Controllers for
Programmable CPU Core Power Supplies

22

______________________________________________________________________________________

than the current limit set by ILIM. The transition time is
given by:

where f

SLEW

= 500kHz

30k

Ω / R

TIME

, V

OLD

is the

original DAC setting, V

NEW

is the new DAC setting, and

V

LSB

is the DAC’s smallest voltage increment. The

additional two clock cycles on the falling edge time are
due to internal synchronization delays. See TIME
Frequency Accuracy in the Electrical Characteristics for
f

SLEW

limits.

The practical range of R

TIME

is 15k

Ω to 150kΩ corre-

sponding to 1.0µs to 10µs per 25mV step. Although the
DAC takes discrete steps, the output filter makes the
transitions relatively smooth. The average inductor cur-
rent required to make an output voltage transition is:

Fault Protection

Output Overvoltage Protection

(MAX1545 Only)

The overvoltage protection (OVP) circuit is designed to
protect the CPU against a shorted high-side MOSFET by
drawing high current and blowing the battery fuse. The
MAX1519/MAX1545 continuously monitor the output for

an overvoltage fault. During normal forced-PWM opera-
tion (SKIP = high), the controller detects an OVP fault if
the output voltage exceeds the set DAC voltage by
more than 13% (min). During pulse-skipping operation
(SKIP = REF or GND), the controller detects an OVP
fault if the output voltage exceeds the fixed 2V (typ)
threshold. When the OVP circuit detects an overvoltage
fault, it immediately sets the fault latch, pulls VROK low,
and activates the shutdown sequence.

This action discharges the output filter capacitor and
forces the output to ground. If the condition that caused
the overvoltage (such as a shorted high-side MOSFET)
persists, the battery fuse blows. The controller remains
shut down until the fault latch is cleared by toggling
SHDN or cycling the V

CC

power supply below 1V.

Overvoltage protection can be disabled through the “no-
fault” test mode (see the No-Fault Test Mode section).

Output Undervoltage Shutdown

The output UVP function is similar to foldback current
limiting, but employs a timer rather than a variable current
limit. If the MAX1519/MAX1545 output voltage is under
70% of the nominal value, the controller activates the
shutdown sequence and sets the fault latch.

Once the controller ramps down to the 0V DAC code
setting, it forces the DL_ low-side gate-driver high, and
pulls the DH_ high-side gate-driver low. Toggle SHDN
or cycle the V

CC

power supply below 1V to clear the

fault latch and reactivate the controller. UVP is ignored
during output voltage transitions and remains blanked

I

C

V

f

L

OUT

LSB

SLEW

Ч

Ч

t

f

V

V

V

for V

ri

g

t

f

V

V

V

for V

falling

SLEW

SLEW

OLD

NEW

LSB

OUT

SLEW

SLEW

OLD

NEW

LSB

OUT













+

1

1

2

sin

SUS

V

DAC

TIME

CLOCK

VROK

VROK BLANKING

VROK BLANKING

OUTPUT SET BY SUS AND S0–S1

OUTPUT SET BY D0–D4

1 LSB PER R

TIME

CYCLE

t

SLEW

t

BLANK

= 24 CLKS

t

SLEW

t

BLANK

= 24 CLKS

Figure 4. Suspend Transition