ATF1502ASV
1615G–PLD–09/02
Notes:
1. Not more than one output at a time should be shorted. Duration of short circuit test should not exceed 30 sec.
2. I
CC3
refers to the current in the reduced-power mode when macrocell reduced-power is turned on.
DC and AC Operating Conditions
Commercial
Industrial
Operating Temperature (Ambient)
0
°
C - 70
°
C
-40
°
C - 85
°
C
V
CC
(3.3V) Power Supply
3.0V
± 3.6%
3.0V
± 3.6%
DC Characteristics
Symbol
Parameter
Condition
Min
Typ
Max
Units
I
IL
Input or I/O Low
Leakage Current
V
IN
= V
CC
-2
-10
µA
I
IH
Input or I/O High
Leakage Current
2
10
I
OZ
Tri-state Output
Off-state Current
V
O
= V
CC
or GND
-40
40
µA
I
CC1
Power Supply Current, Standby
V
CC
= Max
V
IN
= 0, V
CC
Std Mode
Com.
40
mA
Ind.
45
mA
I
CC2
Power Supply Current,
Power-down Mode
V
CC
= Max
V
IN
= 0, V
CC
“PD” Mode
0.75
5.0
mA
I
CC3
(2)
Reduced-power Mode
Supply Current, Standby
V
CC
= Max
V
IN
= 0, V
CC
Std Mode
Com.
25
mA
Ind.
30
mA
V
IL
Input Low Voltage
-0.3
0.8
V
V
IH
Input High Voltage
2.0
V
CCINT
+ 0.3
V
V
OL
Output Low Voltage (TTL)
V
IN
= V
IH
or V
IL
V
CC
= MIN, I
OL
= 8 mA
Com.
0.45
V
Ind.
0.45
Output Low Voltage (CMOS)
V
IN
= V
IH
or V
IL
V
CC
= MIN, I
OL
= 0.1 mA
Com.
0.2
V
Ind.
0.2
V
V
OH
Output High Voltage (TTL)
V
IN
= V
IH
or V
IL
V
CC
= MIN, I
OH
= 2.0 mA
2.4
V
Output High Voltage (CMOS)
V
IN
= V
IH
or V
IL
V
CCIO
= MIN, I
OH
= -0.1 mA
V
CCIO
- 0.2