beautypg.com

Ata6827 [preliminary – Rainbow Electronics ATA6827 User Manual

Page 5

background image

5

4912C–AUTO–10/06

ATA6827 [Preliminary]

Table 3-2.

Output Data Protocol

Bit

Output (Status)

Register

Function

0

TP

Temperature prewarning: high = warning

1

Status LS1

High = output is on, low = output is off; not affected by SRR

2

Status HS1

High = output is on, low = output is off; not affected by SRR

3

Status LS2

Description see LS1

4

Status HS2

Description see HS1

5

Status LS3

Description see LS1

6

Status HS3

Description see HS1

7

n. u.

Not used

8

n. u.

Not used

9

n. u.

Not used

10

n. u.

Not used

11

n. u.

Not used

12

n. u.

Not used

13

SCD

Short circuit detected: set high when at least one high-side or low-side
switch is switched off by a short-circuit condition. Bits 1 to 6 can be used
to detect the shorted switch.

14

OPL

Open load detected: set high, when at least one active high-side or
low-side switch sinks/sources a current below the open load threshold
current.

15

PSF

Power-supply fail: undervoltage at pin VS detected

After power-on reset, the input register has the following status:

Bit 15 Bit 14

Bit 13

(OCS)

Bit 12

Bit 11

Bit 10

Bit 9

Bit 8

Bit 7

Bit 6

(HS3)

Bit 5

(LS3)

Bit 4

(HS2)

Bit 3

(LS2)

Bit 2

(HS1)

Bit 1

(LS1)

Bit 0

(SRR)

x

x

H

x

x

x

x

x

x

L

L

L

L

L

L

L

The following patterns are used to enable internal test modes of the IC. It is not recommended to use these patterns during
normal operation.

Bit 15 Bit 14

Bit 13

(OCS)

Bit 12

Bit 11

Bit 10

Bit 9

Bit 8

Bit 7

Bit 6

(HS3)

Bit 5

(LS3)

Bit 4

(HS2)

Bit 3

(LS2)

Bit 2

(HS1)

Bit 1

(LS1)

Bit 0

(SRR)

H

H

H

H

H

L

L

L

L

L

L

L

L

L

L

L

H

H

H

L

L

H

H

L

L

L

L

L

L

L

L

L

H

H

H

L

L

L

L

H

H

L

L

L

L

L

L

L