Main device (continued) – Rainbow Electronics DS1858 User Manual
Page 14
![background image](/manuals/281239/14/background.png)
DS1858
Dual Temperature-Controlled Resistors with
Three Monitors
14
____________________________________________________________________
MEMORY
LOCATION
(hex)
EEPROM/
SRAM
R/W
DEFAULT
SETTING
(hex)
NAME OF LOCATION
FUNCTION
6F
SRAM
—
—
Conversion updates
—
Bit 7
—
R/W
0
TAU
This bit goes high after a temperature and
address update has occurred for the
corresponding measurement in bytes 60h to
61h. This bit can be written to a 0 by the user
and monitored to verify that a conversion has
occurred.
6
—
R/W
0
V
CC
U
This bit goes high after a V
CC
update has
occurred for the corresponding measurement
in bytes 62h to 63h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.
5
—
R/W
0
MON1U
This bit goes high after a MON1 update has
occurred for the corresponding measurement
in bytes 64h to 65h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.
4
—
R/W
0
MON2U
This bit goes high after a MON2 update has
occurred for the corresponding measurement
in bytes 66h to 67h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.
3
—
—
0
MON3U
This bit goes high after a MON3 update has
occurred for the corresponding measurement
in bytes 68h to 69h. This bit can be written to
a 0 by the user and monitored to verify that a
conversion has occurred.
2
—
—
0
0
—
1
—
—
0
X
—
0
—
—
0
X
—
70
SRAM
R
Alarm flags
—
Bit 7
—
—
—
TMPhi
This alarm flag goes high when the upper limit
of the temperature setting is violated.
6
—
—
—
TMPlo
This alarm flag goes high when the lower limit
of the temperature setting is violated.
5
—
—
—
V
CC
hi
This alarm flag goes high when the upper limit
of the V
CC
setting is violated.
Main Device (continued)