(Continued)

TABLE V Mode Programming

ADC12L038

DI0

DI1

DI2

DI3

DI4

DI5

DI6

DI7

Mode Selected

(Current)

(next Conversion

DO Format

Cycle)

ADC12L034

DI0

DI1

DI2

DI3

DI4

DI5

DI6

ADC12L030

and

DI0

DI1

DI2

DI3

DI4

DI5

ADC12L032

See Tables II III or IV

L

L

L

L

12 Bit Conversion

12 or 13 Bit MSB First

See Tables II III or IV

L

L

L

H

12 Bit Conversion

16 or 17 Bit MSB First

See Tables II III or IV

L

L

H

L

8 Bit Conversion

8 or 9 Bit MSB First

L

L

L

L

L

L

H

H

12 Bit Conversion of Full-Scale

12 or 13 Bit MSB First

See Tables II III or IV

L

H

L

L

12 Bit Conversion

12 or 13 Bit LSB First

See Tables II III or IV

L

H

L

H

12 Bit Conversion

16 or 17 Bit LSB First

See Tables II III or IV

L

H

H

L

8 Bit Conversion

8 or 9 Bit LSB First

L

L

L

L

L

H

H

H

12 Bit Conversion of Offset

12 or 13 Bit LSB First

L

L

L

L

H

L

L

L

Auto Cal

No Change

L

L

L

L

H

L

L

H

Auto Zero

No Change

L

L

L

L

H

L

H

L

Power Up

No Change

L

L

L

L

H

L

H

H

Power Down

No Change

L

L

L

L

H

H

L

L

Read Status Register

No Change

L

L

L

L

H

H

L

H

Data Out without Sign

No Change

H

L

L

L

H

H

L

H

Data Out with Sign

No Change

L

L

L

L

H

H

H

L

Acquisition Time

6 CCLK Cycles

No Change

L

H

L

L

H

H

H

L

Acquisition Time

10 CCLK Cycles

No Change

H

L

L

L

H

H

H

L

Acquisition Time

18 CCLK Cycles

No Change

H

H

L

L

H

H

H

L

Acquisition Time

34 CCLK Cycles

No Change

L

L

L

L

H

H

H

H

User Mode

No Change

H

X

X

X

H

H

H

H

Test Mode

No Change

(CH1 – CH7 become Active Outputs)

Note

The A D powers up with no Auto Cal no Auto Zero 10 CCLK acquisition time 12-bit

a

sign conversion power up 12- or 13-bit MSB first and user mode

X

e

Don’t Care

TABLE VI Conversion Read Data Only Mode Programming

CS

CONV

PD

Mode

L

L

L

See Table V for Mode

L

H

L

Read Only (Previous DO Format)

No Conversion

H

X

L

Idle

X

X

H

Power Down

X

e

Don’t Care