Absolute Maximum Ratings*

Operating Range

The operating range defines the limits where function is guaranteed.
Electrical limits of applied signals are given in the operating conditions section.

Operating
Precautions

Shorting the video outputs to any other pin, even temporarily, can permanently damage
the on-chip output amplifier.

Operating Conditions

Storage Temperature .................................... -55°C to + 150°C

*NOTICE:

Stresses above those listed under absolute max-
imum ratings may cause permanent device fail-
ure. Functionality at or above these limits is not
implied. Exposure to absolute maximum ratings
for extended periods may affect device reliability.

Operating Temperature ...............................

-40°C to + 85°C

Thermal Cycling.........................................................15°C/mm

Maximum Applied Voltages:

A2, A6, B2, C5, B5, C3, A5, C2, A3, A7, B7, C4
B4, C6, C7, A4, V7, W8, V8, AA8, V6, AA5.......... -0.3V to 15V

V2, V3, V4, V5, W2, W3, W4, W5
W6, C1, AA6 ......................................................-0.3V to 15.5V

C8 ......................................................................... -0.3V to 12V

AA7, V1, W1, W7, A8, B8, B6, B1, A1, B3 ............. Ground 0V

Table 1. DC Characteristics

Parameter

Symbol

Value

Unit

Min

Typ

Max

Output amplifier drain supply

VDD1, VDD2,

VDD3, VDD4

14.5

15

15.5

V

Screen voltage

VDDP

14.5

15

15.5

V

Reset bias

VDR

14.5

15

15.5

V

Antiblooming diode bias

VA

14.5

15

15.5

V

Register output gate bias

VGS

2.2

2.5

2.8

V

Output amplifier source supply

VS1,2,3,4

0

V

Ground

VSS

0

V