beautypg.com

Assemblies with internal bearings (continued) – Grain Systems Custom, Utility and Bulk Tank Augers PNEG-1445 User Manual

Page 24

background image

24 PNEG-1445 6", 8", 10" and 12" Custom Augers

4. Assembly

Assemblies with Internal Bearings (Continued)

3. With flight sections bolted together slide extension tube flush against main auger tube.

(See Figure 4S.)

Figure 4S

4. With tube sections pressed flush against each other slide connecting band over the tubes aligning

the holes. Reach through the access hole and align hanger bearing with the bolt hole. Attach the
hanger bearing to the tube using assigned hardware.

(See Chart below

and

Figure 4T.)

Figure 4T

Hanger Bearing Bolt

8"

5/8"-11 x 1-3/4" Grade 8 Bolt

10"

5/8"-11 x 1-3/4" Grade 8 Bolt

12"

3/4"-10 x 2" Grade 8 Bolt

(

See Chart above

for bolt sizes.)