beautypg.com

Troubleshooting, Chapter 11 troubleshooting – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-751-G2 User Manual

Page 73

background image

PNEG-751-G2 12" Series II Sweep 131' and 135' Diameter

73

11. Troubleshooting

Problem

Possible Cause

Solution

1. Sweep does not run.

1. Foot switch may not be actuated.

1. Make sure the foot switch is depressed

and the switch is operating properly.

2. Overloads may be tripped.

2. Reset the overloads.

3. Adjustable overloads not set correctly.

3. Set overload to 10% over the value

listed on motor nameplate for full
load amps.

2. Low capacity.

1. The auger may not be fully loaded.

1. Make sure the grain is flowing into the

auger, making it fully loaded.

2. The auger is moving too slowly.

2. Check the auger speed. Low

capacity results from speeds slower
than recommended.

3. Sweep does not move

around the bin.

1. The control panel may not be in

“automatic mode”.

1. Turn the switch to “automatic mode”.

2. The amp meter is not properly adjusted.

2. Set the amp meter so the running amps

of the auger motor turns ON the
drive motor.

3. The drive chain may be broken.

3. Repair the drive chain.

4. The sweep is vibrating.

1. The auger may have foreign materials

in it.

1. Remove the foreign material.

2. The hanger bearings may be worn.

2. Replace the hanger bearings.

3. The flight connections may be loose.

3. Tighten all of the flight connecting bolts.

4. The flighting may be worn.

4. Replace all the flighting sections that

are worn.