Data logger setup – Grain Systems PNEG-1743 User Manual
Page 29

5. Operations
PNEG-1743 Vision for Tower Dryers
29
7. Data Logger Setup:
By turning the data logger on, it records the following
parameters of the dryer every 5 minutes.
a. Dryer grain temperature
b. Incoming grain temperature
c. Incoming grain moisture
d. Outgoing grain temperature
e. Outgoing grain moisture
f. Meter roll speed
g. Bin number
h. Hour
i. Minute
Figure 5Q
Looking Up Data Logger Records
1. Go to our website (www.grainsystems.com) and click on the “GRAIN DRYER VISION
CONTROL” link at the right side of the page.
2. Download the “LOGVIEWER INSTALLER” at the top right of the page to the desktop.
3. Execute the “LOGVIEWER SETUP” file and install the program.
4. Open the “Dryer Data Logviewer” program.
5. Navigate the menu to “File” -> “Open”. Select the log file that was downloaded
from Vision.
6. Data can be exported to an Excel spreadsheet by “File” -> “Export to spreadsheet file”.
- PNEG-1890 (16 pages)
- PNEG-595 (26 pages)
- PNEG-1472 (30 pages)
- PNEG-897 (58 pages)
- PNEG-838 (4 pages)
- PNEG-1755 (36 pages)
- PNEG-524 (24 pages)
- PNEG-1080 (2 pages)
- PNEG-728 (47 pages)
- PNEG-673 (57 pages)
- PNEG-1717 (88 pages)
- PNEG-823 (42 pages)
- PNEG-630-6S (23 pages)
- PNEG-1876 (80 pages)
- PNEG-102 (2 pages)
- PNEG-366 (51 pages)
- PNEG-1626 (1 page)
- PNEG-1874 (78 pages)
- PNEG-1798 (34 pages)
- PNEG-1927 (4 pages)
- PNEG-924 (2 pages)
- PNEG-582 (26 pages)
- PNEG-012 (46 pages)
- PNEG-1797 (86 pages)
- PNEG-546 (26 pages)
- PNEG-951 (102 pages)
- PNEG-1650 (92 pages)
- PNEG-1649 (50 pages)
- PNEG-1376 (88 pages)
- PNEG-361 (46 pages)
- PNEG-338 (32 pages)
- PNEG-1276 (78 pages)
- PNEG-1283 (22 pages)
- PNEG-1089 (14 pages)
- QSG-001 (2 pages)
- PNEG-950 (96 pages)
- PNEG-1590 (3 pages)
- PNEG-501 (33 pages)
- PNEG-1447 (68 pages)
- PNEG-707GSI (446 pages)
- PNEG-349 (32 pages)
- PNEG-236 (22 pages)
- PNEG-743 (16 pages)
- PNEG-900 (54 pages)
- PNEG-1935 (92 pages)