3. Vision Control Panel
Figure 3A
Control Power Switch
The Vision control system is turned ON or OFF with this switch.
NOTE: This switch does not disconnect the power that is present at the breakers, contactors, transformer(s),
fuses or other electrical components found in the control or power box. Turn the main disconnect
handle to the OFF position prior to servicing any of the installed components.
Stop Button
This button stops all dryer functions except the blower (fan). If the blower switch, noted on the panel as
the Fan switch, is in the ON position, the blower will continue to run for 15 minutes. If you desire the
blower to be OFF, turn the blower switch to the OFF position. If an automatic dryer shutdown occurs,
first determine and correct the cause of the shutdown. Then, press the Stop button to reset the dryer
before restarting.
Fan switches
Load switch
Unload switch
Outside
Light switch
Control
Power switch
Stop button
Start switch
Meter Roll
Adjustment
Touch screen
Heater switches