Operations, Chapter 5 operations, Default operation screen – Grain Systems PNEG-1743 User Manual
Page 19: Operations default operation screen

PNEG-1743 Vision for Tower Dryers
19
5. Operations
Operations
Default Operation Screen
Figure 5A
The “Default Operation Screen” is divided into five (5) sections.
1. Dryer Operation Animation: Located on the left side of the “Default Operation Screen”, the dryer
operation animation shows the status of the fans/heaters, load and unload augers and meter rolls.
It will also display the grain temperature, moisture content, moisture control setpoint and the
bushel counter.
2. Dryer Status: Located at the very top of the right side of the “Default Operation Screen”, the dryer
status will tell the user if the dryer is stopped, started, loading or unloading.
3. Dryer Status Chart: This chart, located directly under dryer status, will show the grain temperature,
moisture in/out, temperature out and meter roll output (M.R.O) over a period of time.
4. Plenum(s): Located directly below dryer status chart, the plenum section will show temperature
setpoint, actual plenum temperature and burner status.
5. Configuration Buttons: Select from “Timers”, “Temp”, “Setup”, “View” and “M/C” buttons.
Dryer Operation
Animation
Dryer Status
Dryer Status
Charts
Plenum(s)
Configuration
Buttons