beautypg.com

Capacities and specifications, Introduction, 12" series ii sweep 16" series ii sweep – Grain Systems Bucket Elevtors, Conveyors, Series II Sweeps PNEG-1366 User Manual

Page 16

background image

4. Introduction

16

PNEG-1366 12" and 16" Series II Sweep Quick Disconnect Control Box Kit

Capacities and Specifications

1. Use the

Chart below

to determine the horsepower required.

Due to continual improvements, GSI designs and specifications are subject to change without notice.

Bin

Diameter

12" Series II Sweep

16" Series II Sweep

Drive

HP

Bushel/MT per Hour

Horsepower

Length

Pivot to End

Drive

HP

Bushel/MT per Hour

Horsepower

Length

Pivot to End

5000/125

6000/155

7000/180

8000/205

9000/230

10000/255

36'

2

7.5

7.5

7.5

16.79' (5.12 m)

2

7.5

7.5

7.5

16.85' (5.14 m)

37'

2

7.5

7.5

7.5

17.79' (5.43 m)

2

7.5

7.5

7.5

16.85' (5.14 m)

39'

2

7.5

7.5

7.5

18.79' (5.73 m)

2

7.5

7.5

7.5

17.85' (5.44 m)

40'

2

7.5

7.5

7.5

18.79' (5.73 m)

2

7.5

7.5

7.5

18.75' (5.72 m)

42'

2

7.5

7.5

7.5

19.79' (6.04 m)

2

7.5

7.5

10

19.85' (6.05 m)

43'

2

7.5

7.5

7.5

20.79' (6.34 m)

2

7.5

7.5

10

19.85' (6.05 m)

45'

2

7.5

7.5

7.5

20.79' (6.34 m)

2

7.5

7.5

10

20.85' (6.36 m)

48'

2

7.5

7.5

7.5

22.79' (6.95 m)

2

7.5

10

10

22.85' (6.96 m)

49'

2

7.5

7.5

7.5

22.79' (6.95 m)

2

7.5

10

10

22.85' (6.96 m)

51'

2

7.5

7.5

10

23.79' (7.26 m)

2

7.5

10

10

23.85' (7.27 m)

54'

2

7.5

7.5

10

25.79' (7.86 m)

2

10

10

10

25.85' (7.88 m)

55'

2

7.5

7.5

10

25.79' (7.86 m)

2

10

10

10

25.85' (7.88 m)

57'

2

7.5

7.5

10

26.79' (8.17 m)

2

10

10

10

26.85' (8.18 m)

59'

2

7.5

7.5

10

27.79' (8.47 m)

2

10

10

15

27.85' (8.49 m)

60'

2

7.5

7.5

10

28.79' (8.78 m)

2

10

10

15

28.85' (8.79 m)

62'

2

7.5

7.5

10

29.79' (9.08 m)

2

10

10

15

29.85' (9.10 m)

63'

2

7.5

7.5

10

29.79' (9.08 m)

2

10

10

15

29.85' (9.10 m)

66'

2

7.5

7.5

10

31.79' (9.69 m)

2

10

15

15

31.85' (9.71 m)

68'

2

7.5

7.5

10

32.79' (10.00 m)

2

10

15

15

32.85' (10.01 m)

69'

2

7.5

7.5

10

32.79' (10.00 m)

2

10

15

15

32.85' (10.01 m)

72'

2

7.5

7.5

10

34.79' (10.61 m)

2

15

15

15

34.85' (10.62 m)

75'

2

10

10

10

35.79' (10.91 m)

2

15

15

15

35.85' (10.93 m)

78'

2

10

10

10

37.79' (11.52 m)

2

15

15

15

37.85' (11.54 m)

80'

2

10

10

10

38.79' (11.83 m)

2

15

15

15

38.85' (11.84 m)

81'

2

10

10

10

38.79' (11.83 m)

2

15

15

15

38.85' (11.84 m)

84'

2

10

10

15

40.79' (12.44 m)

2

15

15

15

40.85' (12.45 m)

87'

2

10

10

15

41.79' (12.74 m)

2

15

15

20

41.85' (12.76 m)

88'

2

10

10

15

42.79' (13.05 m)

2

15

15

20

42.85' (13.06 m)

90'

2

10

10

15

43.79' (13.35 m)

2

15

15

20

43.85' (13.37 m)

91'

2

10

10

15

43.79' (13.35 m)

2

15

15

20

43.85' (13.37 m)

92'

2

10

10

15

44.79' (13.66 m)

2

15

20

20

44.85' (13.67 m)

95'

2

10

15

15

45.79' (13.97 m)

2

15

20

20

45.85' (13.98 m)

98'

2

10

15

15

47.79' (14.57 m)

2

15

20

20

47.85' (14.58 m)

105'

3

15

15

20

50.79' (15.48 m)

3

20

20

20

50.85' (15.50 m)

113'

3

15

15

20

54.79' (16.70 m)

3

20

20

20

54.85' (16.72 m)

120'

3

15

15

20

58.79' (17.92 m)

3

20

20

20

58.85' (17.94 m)

Electrical controls and wiring should be installed by a qualified electrician. The
motor disconnect switches and conductor cables should comply with the National
Electrical code and any local codes which apply. Reset and motor starting
stations should be located so the operator can see that all personnel are clear
of the equipment.