Electrical (bottom module) – Grain Systems PNEG-1404 User Manual
Page 71
4. Electrical (Bottom Module)
PNEG-1404 Vision Series Model 2300 Portable Dryers
71
Left Grain High-Limit Thermostat Parts List
Ref #
Part #
Description
1
D03-0117
Lamp, 90° w/ Junction Box
1
D03-0575
Bulb, 100W 130V Rough Service
2
D03-0057
Conduit, 1/2" EMT Metallic
3
FH-6972
Enclosure, 4 x 4 x 2-1/2 White PVC
4
D03-0005
Grain Thermostat High-Limit 10' 210° (for 14' Dryers Only)
4
D03-0378
Grain Thermostat High-Limit 24' 210° (for Dryers that are 16' and Longer)
5
D01-0254
High-Limit Mounting Bracket
6
D03-0004
Plenum Thermostat 10' 300° (for 14' Dryers Only)
6
D03-0377
Plenum Thermostat 24' 300° (for Dryers that are 16' and Longer)
7
120-1538-4
Sealtite, PVC 1/2"
8
006-1377-1
Elbow, 1/2" 90° PVC w/ Nut
9
006-1360-4
Seal, 1/2" Straight PVC w/ Nut
10
D03-0054
Connector 1/2" EMT Compression
11
TFC-0075
Cover Aluminum, Conduit Body
12
HF-7236
Plenum Thermistor Bolt
13
S-968
Flange Nut, 3/8"-16 ZN Grade 5 Wide Flange
14
D03-0375
Conduit Body, LL Type
15
DM60001
Pipe, SCH 40 1/2"
16
GT3-0241
Clamp, Beam 1/2"
17
HH-1096
Clamp, 1/2" Conduit
18
D03-0075
Connector, 1/2" Liquid-Tite to 1/2" EMT
The following components make up the grain high-limit conduits that run through the grain columns. The conduit
assemblies are not shown in the photos.
N/S
D03-0057
Conduit, 1/2" EMT Metallic
N/S
D03-0054
Connector, 1/2" EMT Compression (2/Conduit; 1 at Each End of the Dryer.)
N/S
D33-0002
Coupler, 1/2" EMT Compression (Couples the Lengths of 1/2" EMT)
N/S
FH-6972
Enclosure 4 x 4 x 2-1/2 White PVC (As of 2003 a 4 x 4 enclosure has been added to these
assemblies and is mounted on the rear column end panels into which the grain high-limit
thermostat conduits now terminate.)