Measuring and special equipment required, Chapter 6 measuring and special equipment required – Grain Systems PNEG-1798 User Manual
Page 12
![background image](/manuals/277551/12/background.png)
12
PNEG-1798 Tower and T-Series Dryers Vaporizer
6. Measuring and Special Equipment Required
6.1. Nitrogen gas, large cylinder.
6.2. Regulator, single stage with CGA 580 fitting, nitrogen gas service with gauges. (Must regulate to
200 PSIG -
.)
6.3. Hose with fittings on each end, high pressure (rated for > 500 PSIG).
6.4. Gauge, pressure (0-300 PSIG) or equivalent digital electronic pressure transducer or pressure
transmitter with readout device.
6.5. Power cord 16/3 AWG or 14/3 AWG with 120 VAC 3 prong plug on one end, bare wires and wire nuts
for the other end. (This will be used to power the 3/4" normally closed ASCO liquid line solenoid valve
during leak testing in
,
.)
6.6. Leak test solution, industrial grade. (To detect nitrogen gas leaks.)
6.7. Pipe cutting and threading equipment for 2", 1-1/4" and 3/4" piping.
6.8. Pipe thread sealant, industrial grade with PTFE and/or teflon tape.