beautypg.com

C-band / ku-band lnb, 1000h series ku-band pll, 1000hs series ku-band pll – Toner Cable 3000 Series Digital C-Band PLL LNB User Manual

Page 2

background image

Specifications Subject To Change Without Notice

Rev 11-10

©Toner Cable Equipment, Inc.

969 Horsham Road

l

Horsham, Pennsylvania 19044 USA

l

Phone: 215-675-2053 Fax: 215-675-7543

l

[email protected]

FREQUENCY BANDS AVAILABLE

Typical Service

1000HA

1000HB

1000HC

Input Frequency (GHz)

11.70 to 12.20

12.25 to 12.75

10.95 to 11.70

L.O. Frequency (GHz)

10.75

11.30

10.00

Output Frequency (MHz)

950 to 1450

950 to 1450

950 to 1700

TYPICAL SPECIFICATIONS

Noise Figure

0.7 to 0.9 dB
depending on model number

L.O. Stability

±10 kHz to ±25 kHz

(over temperature excl. offset)

(See HS1000 for < 5 kHz
L.O. stability)

Phase Noise

-75 dBc/Hz at 1 kHz

(SSB)

-80 dBc/Hz at 10 kHz
-95 dBc/Hz at 100 kHz

Input VSWR

2.2 : 1

Output VSWR

2.2 : 1

Conversion Gain

60 dB

Output P1dB

5 dBm

Power Requirements

+15 to +24 V supplied through
center conductor of IF cable

Current Drain

200 mA

Input Waveguide

WR75

Dimensions

110 (L) x 42 (W) x 42 (H) mm
(4.3 x 1.7 x 1.7 in)

Weight

300 g / 10.6 oz

Temperature Range

-40°C to +60°C

1000H Series KU-Band PLL

FREQUENCY BANDS AVAILABLE

Typical Service

HS1000A

HS1000B

HS1000C

Input Frequency (GHz)

11.70 to 12.20

12.25 to 12.75

10.95 to 11.70

L.O. Frequency (GHz)

10.75

11.30

10.00

Output Frequency (MHz)

950 to 1450

950 to 1450

950 to 1700

TYPICAL SPECIFICATIONS

Noise Figure

0.7 to 0.9 dB

L.O. Stability

±5 kHz to ±2 kHz

(after 60 sec )
Phase Noise

-75 dBc/Hz at 1 kHz

(SSB)

-80 dBc/Hz at 10 kHz
-95 dBc/Hz at 100 kHz

Input VSWR

2.2 : 1

Output VSWR

2.2 : 1

Conversion Gain

60 dB

Output P1dB

5 dBm

Power Requirements

+15 to +24 V supplied through
center conductor of IF cable

Current Drain

200 mA

Input Waveguide

WR75

Dimensions

110 (L) x 42 (W) x 42 (H) mm
(4.3 x 1.7 x 1.7 in)

Weight

300 g / 10.6 oz

Temperature Range

-40°C to +60°C

1000HS Series KU-Band PLL

C-Band / KU-Band LNB

s