Laserplus, Laserplus chassis – Toner Cable LaserPlus 1GHz High Density CATV Optical Transmission System User Manual
Page 4
Specifications Subject To Change Without Notice
Rev 06-11
©Toner Cable Equipment, Inc.
969 Horsham Road
l
Horsham, Pennsylvania 19044 USA
l
Phone: 215-675-2053 Fax: 215-675-7543
l
LaserPlus
1 GHz High Density Compact CATV Optical Transmission System
The LaserPlus Model LP-CH-16 Chassis fits into a 19-
inch EIA rack, and holds up to 15 interchangeable, hot-
swappable, plug-in application modules. Each
chassis requires one power supply & accepts a 2nd for
hot redundant backup, & has provisions for both local
monitoring & remote SNMP element management.
The chassis is very compact, occupying only 5.25” (3
RU) of rack space. Universal slots accept almost any
“mix-and-match” combination of Olson Technology, Inc.
LaserPlus Model LP-x transmitter, receiver, EDFA,
block downconverter, passive optical coupler or WDM application modules, to accommodate a limitless variety of service
delivery architectures and provide flexibility and scalability in headend/hub design and zone arrangements.
It also includes an integrated internal fiber management tray. The connecting optical fiber(s) can enter the chassis from the
front, or from fiber routing apertures located on either (or both) sides of the chassis. Once the fiber connection is made, the
fiber cable can be secured in an integrated fiber management tray, located above the application modules. Drop slots are
conveniently placed along the tray to assure minimum fiber clutter in front of the modules. The application modules slide into
the chassis from the front of the rack, and all RF coaxial cables are connected at the rear.
A single AC or DC power supply module plugged into the primary power supply slot# 16 is sufficient to power a fully loaded
LaserPlus chassis; two power supplies (in slots# 15 & 16) may be used to provide hot-redundant backup. For maximum fail-
safe protection, an AC module can be used in combination with a DC module to provide simultaneous AC and DC powering to
the LaserPlus chassis.
LaserPlus Chassis
ELECTRICAL, ENVIRONMENTAL & MECHANICAL PARAMETERS:
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .5.25” H x 19” W x 14.5” D (13.3 cm x 48.3 cm x 36.8 cm)
Weight (Empty) . . . . . . . . . . . . . . . . . . . . . . .10 lb (4.54 kg)
Operating Temperature Range . . . . . . . . . . .0°C to +50°C (+32°F to +122°F)
(Air temperature measured at air inlet of Model LP-CH-16 chassis)
Humidity Range . . . . . . . . . . . . . . . . . . . . . . .to 95% non-condensing
[Recommended for use only in non-condensing environments]
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Four fans plenum-mounted; user-replaceable (PN# 037-000405)
Module Slots . . . . . . . . . . . . . . . . . . . . . . . . .1-14=application modules; 15=apps or PS; 16=power supply
Powering . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.25VDC per module; 90-264 VAC or -48VDC; < 150 Watts
[Requires use of 1 or 2 Model LP-PS-x power supply module(s)]
CHASSIS INTERFACES:
Local Status Alarms Connector: . . . . . . . . . .DB-25
Electrical Interface: Relay Contact Closure: 100mA @ 25VDC
[Provides ground closures on alarm: PINS 1-15 = SLOTS 1-15;
PIN 17 = Cooling; PIN 24 = Summary; PIN 25 = GND]
SNMP Agent (Optional) Connector: . . . . . . .RJ-45
Electrical Interface: 10BaseT Ethernet
[Requires Model LP-CH-SNMP-1 element managment agent]