CONFIGURATION OF THE OUTPUT MODES OF OUTPUT 1, 2 AND 3 (Locations 51, 52 & 53)
The three relay outputs of this keypad are programmable for Start/Stop or Timing modes. Apart from
the door access control, alarm arm-disarm control, they are also
universal timers for automatic
operators in industry with their 99,999 seconds (over 24 hours) programmable timer.
OUTPUT LOCATIONS
51
-- Location for Output 1
52
-- Location for Output 2
53
-- Location for Output 3
OUTPUT MODE & TIMING
0
– Start /Stop Mode (Toggle)
The number 0 sets the output to the
Start / Stop mode. The output Starts when an User PIN and/
or Card is entered/read; the output
Stops when an User PIN and/or Card is entered/read again.
1
-
99999
Seconds Momentary --- (Default -- Momentary 5 Seconds)
The output can be set in
Momentary Mode with the time of 1 second to 99,999 seconds. The output
will reset automatically when the time expires OR it can be
RESET manually at anytime with the
Super User Code that operates the desired output before the end of the time.
Example : Reset Output 1 --
#
1
------------- Output 1 resets
Reset Output 2 --
#
2
------------- Output 2 resets
Reset Output 3 --
#
3
------------- Output 3 resets
PERSONAL SAFETY AND SYSTEM LOCK-OUT (Location 60)
SAFETY & LOCK-OUT OPTIONS
The Options are represented by their Mode Numbers in programming. They are described below:
1
--- After 10 successive false Card/User Code trials, the keypad locks during 60 seconds.
-- (Default)
2
---
5
-
10
---
Example : Release the lock-out --
#
9
00
--- Disappearance of all the above lock-out securities.
SUPER USER CODE
SUPER USER CODE
SUPER USER CODE
1 to 2 Digits
LOCK-OUT MODES VALIDATION
LOCATION
60
#
SUPER USER CODE
OUTPUT MODE & TIME
VALIDATION
LOCATIONS
51
-
53
0
or
1
-
99999
#
33
MASTER
INDIVIDUAL
After 10 successive false Card/User Code trials, activates the Duress output to switch to (-)
ground.
The Duress Output can be released with any user PIN or Card in the User Group 1 or Super
User PIN.
Selection of after 5 to 10 successive Card/User Code trials, the keypad locks during
15 minutes.
The keypad can be reset to release the lock-out with the “Super User Code” in the
following way.