Velleman HAA2801 User Manual
Page 32
Example 2: Set a “Duress Code” with the number of “2 3 9 8 0” for Output 2
42
01
23980
#
(a) (b) (c) (d)
(a) Duress Code Programming for Output 2, (b) Duress Code ID, (c) The Duress Code, (e) Entry
Confirmation
Example 3: Delete an Output 1 “Duress Code” from Duress Code ID
01
in the memory
41
01 #
(a) (b) (c)
(a) Duress Code Programming for Output 1, (b) The Duress Code ID, (c) Delete Confirmation
Example 4: Clear The Whole Group of Duress Codes from Location
41
:
41
0999 #
(a) (b) (c)
(a) Group Location
41
, (
b) The Group Deletion Command, (c) Confirmation, all Duress Codes in
Location
41
are cleared.
THE OPERATION AND FUNCTION OF THE DURESS CODE
The Duress Code(s) has double actions when it is keyed in. It activates the Duress Output (for duress
alarm) and at the same time activates the specific Relay Output 1, 2 or 3 just like a normal User PIN.
The Duress Code always activates its Relay Output in its group, but, does not de-activate (stop) the
Duress Output.
ONLY a normal User PIN or Card in anyone of the user groups, or a Super User
PIN can reset (de-activate) the Duress Output.
For Example:
Key in The Duress Code 3 3 6 9 of the Group 1 (for Output 1) To Command The Duress Function :
3369#
----- Duress Output activates (switches to (-) ground) & Output 1 activates.
Key in The Duress Code 3 3 6 9 in Group 1 (for Output 1) Again :
3369#
----- Duress Output keeps activating and no change in its state (keeps to (-) ground)
& Output 1 activates again.
Key in A Normal User PIN 1 3 6 9 in Group 1 (for Output 1):
1369#
----- Duress Output resets (back to OFF state) but has no function on Output 1.
Report Duress in EM Card Operation
The Duress Codes are Prime User Codes in the system. In the “
EM Card + Secondary User PIN” or
“
EM Card + Common User PIN” operation, they can be used to replace the “Secondary User PIN” or
the “Common User PIN” to operate the specific output and report a duress alarm event. Programming
is not required. The system has the function automatically while Duress Code exists.
Operation : Taking Duress Code 3 3 6 9 in Group 1 for Output 1 As Example
3369 #
(a) (b) (c)
(a)
(b)
(c)
NOTE: Duress Event can not be reported in the operation of only EM Card alone.
Read Card
32
Put the EM card close to the reader. One-beep confirms the reading and 30 seconds waiting
time is given for the entry of the Duress Code, the Amber LED keeps flashing
Key in the Duress Codes 3 3 6 9 for operating the Output 1
Confirm it with the # key. Output 1 activates in a normal way and the Duress Output also
activates to report Duress Event to an alarm system if connected.