Velleman HAA2801 User Manual
Page 31
Example 3: Delete a “Visitor Code” from Vistor ID
02
in the memory
40
02 #
(a) (b) (c)
(a) Visitor Code Programming, (b) The Visitor ID, (c) Delete Confirmation
Example 4: Clear all “Visitor Codes” from Location
40
40
0999 #
(a) (b) (c)
(a) Visitor Code Location, (b) The Deletion Command Code, (c) Confirmation, all Visitor Codes are cleared
DURESS CODES (FOR OUTPUTS 1, 2 & 3) (Location 41, 42 & 43)
The Duress Codes are prepared for those
Important Persons in case of DURESS while he operates
the access control keypad. The duress code operates like a normal User PIN for Output 1, 2 or 3, and
at the same time activates the Duress Output without any indication. The user may use it to report an
emergency and ask for help silently when he is forced to operate the keypad if the Duress Output is
connected with a security system.
NOTE: The Duress Codes are always valid. They are not governed by any inhibit or lock-out function
in the system.
OUTPUT LOCATIONS
41
– Duress Codes for Output 1
42
– Duress Codes for Output 2
43
– Duress Codes for Output 3
DURESS CODE IDs
ID
01
-
50
50 Duress Codes Are Allowed for The Output 1
ID
01
-
10
10 Duress Codes Are Allowed for The Output 2
ID
01
-
10
10 Duress Codes Are Allowed for The Output 3
0999
=
Clear all the Duress Codes from the selected Location group.
Please see the programming example below for the details.
THE DURESS CODES
50, 10 and 10 Duress Codes can be programmed for Output 1, 2 and 3 respectively. They are stored
in their two-digit Code ID box. When a new Code is put into the same Code ID box, the old code is
replaced.
The Duress Codes are 4-8 digits for Manual Mode code entry.
The Duress Codes MUST be in the same digit length with the Master Code for Auto Mode code
entry.
Always set a Duress Code that is easy to remember in
Panic Situation. Only one number different
from the daily used User PIN is highly recommended.
Example: User PIN is 1 3 6 9, then 3 3 6 9 or 1 3 6 0 might be a good choice for the Duress Code.
The
Duress Code can also be used to replace the Secondary User PIN or Common User PIN in
Card reading for the Duress reporting.
EXAMPLES:
Example 1: Set a “Duress Code” with the number of “3 3 6 9” for Output 1
41
01
3369
#
(a) (b) (c) (d)
(a) Duress Code Programming for Output 1, (b) Duress Code ID, (c) The Duress Code, (e) Entry
Confirmation
41
-
43 01
-
50
#
4-8 DIGITS
DURESS CODE VALIDATION
LOCATIONS
CODE ID
31
INDIVIDUAL