4) Example 4 -- EM Card + Common User PIN :
i) Programming :
10
4
003
#
(a) (b) (c) (d) (e)
(a)
(b)
(c)
(d)
(e)
ii) Operation : (while the system is back to operation mode)
#
(a) (b) (c)
(a)
(b)
(c)
5) Example 5 -- Delete an User PIN & / or EM Card (for O/P 1, 2 or 3) :
i) Delete An User PIN or A Lost EM Card
10
5 #
(a) (b) (c) (d)
(a)
(b)
(c)
(d)
ii) Delete an EM Card
10
5 #
(a) (b) (c) (d)
(a)
(b)
(c)
(d)
6) Example 6 – Clear The Whole Group of Users :
Whole group of users including the PINs and Cards can be cleared with the following command.
10
0999
#
(a) (b) (c)
(a)
(b)
(c)
7) Example 7 – Report A Duress While Using EM Card :
The Duress Codes are Prime User Codes in the system. In the “EM Card + Secondary User PIN”
or “EM Card + Common User PIN” operation, they can be used to replace the “Secondary User
PIN” or the “Common User PIN” to operate the specific output and report a duress alarm event.
Programming is not required. The system has this function automatically while Duress Code exists.
Read Card
User ID
Read Card
Common User PIN
Read Card
29
The card is programmed for operating of the Output 1
The operation is “EM Card + Common User PIN”
Take ID number 003 in Group 1 to store the card, which is one of the IDs in 000-999
Put the card close to the reader. One beep confirms the reading. (No need to key in a Common
User PIN but there
MUST be a Common User PIN already recorded in Location 03; (or 04, 05 if
for O/P 2, O/P 3).
Press # to store the “Card” into memory. Two-beep confirms a valid entry
Put the EM card close to the reader. One-beep confirms the reading and 30 seconds waiting
time is given for the entry of the Common User PIN, the Amber LED keeps flashing
Key in the Common User PIN “1 3 5 7” (the number programmed in “Location 0 3” for Output 1
in the previous Example)
Confirm it with the # key. Output 1 activates
Key in the User Group that the User ID belongs to. “10” for the Group 1, “20” for the Group 2,
and “30” for the Group 3
Key in “5” that is the Command Code for making a deletion here
Key in the User ID that stored the User PIN, the lost EM card or the EM Card+User PIN
Press the # key. Two-beep confirms a valid entry and the PIN and/or Card in that User ID is
cleared
Key in the User Group that the EM Card belongs to. “1 0” for the Group 1, “2 0” for the Group 2,
and “3 0” for the Group 3
Key in “5” that is the Command Code for making a deletion here
Put the EM card close to the reader. One-beep confirms the reading. Read the Card only also
makes a valid deletion to the Card working with the Common User PIN or the Secondary User
PIN
Press the # key. Two-beep confirms a valid entry. The EM Card in that User ID is cleared. Key in the
User ID is not required.
The User Group 1 – “
10” is selected to be cleared. “20” for Group 2 & “30” for Group 3
Key in the Group Deletion Command,
0 9 9 9
Confirm the deletion with #. All the User PINs and Cards in the Group 1 are cleared. It takes few
seconds to a minute to complete depending on the data stored.