Trek 950 Nozzle Ionizer User Manual
Page 2
Model 950 Accessories (supplied)
Model 950 Optional Accessories
Operator’s Manual
Nozzles - Please select from the part numbers listed above
Signal to Power Supply Cable
AC Adapter Kits - Please select from the part numbers listed
above
Model 10/40A Specifications
Model 950 Nozzle Ionizer Specifications
Copyright © 2012 TREK, INC.
All specifications are subject to change.
1230/DEC
All specifications are with no load unless otherwise specified.
States
LED State
Relay State
Power
H.V. C.C.
Alarm
Alarm N.C.
Alarm N.O.
C.C
Power On
Normal
o
o
ON
OFF
OFF
HV Pr oblem
o
o
O FF
ON
OFF
Cleaning
Required
o
o
o
ON
OFF
ON
H.V. Off
o
ON
OFF
OFF
Po wer O ff
O FF
OFF
OFF
CERTIFICATE AND COMPLIANCE
TREK, INC. certifies that each Model 950 is tested and calibrated to specifications using
measurement equipment traceable to the National Institute of Standards and Technology
or traceable to consensus standards.
FEATURES
PERFORMANCE (Con’t.)
ACCESSORIES SUPPLIED
Ion Generation
Gauge Pressure (when connecting Nozzle
Instruction Manual
High-frequency Corona discharge
Ionizer and optional nozzle)
Signal to Power Supply Cable
-S (standard)
0.05 to 0.60MPa
High Voltage Protection
-TT(Teflon tube)
0.05 to 0.50MPa
OPTIONAL ACCESSORIES
Alarm and turn-off upon detection
-100B ~ 300B
0.05 to 0.60MPa
of abnormal operation
-100BL ~ 200BL
0.05 to 0.60MPa
Nozzles
-120PSP
0.05 to 0.50MPa
Discharge Needle Contamination
-C100 ~ C500
0.05 to 0.30MPa
Detection
-ST(Silicon tube)
0.05 to 0.30MPa
An alarm is triggered and an output
-60S
0.05 to 0.60MPa
relay is energized if the discharge
-F
0.05 to 0.60MPa
needle becomes contaminated
GENERAL
Optional Air Tube for Ion Air Transfer Power Supply Voltage
High-frequency ionization enables
24 VDC ±5% (2.4VA)
ion air transfer to difficult-to-reach
tight locations via an optional tube
Operating Conditions
Temperature
Easy Maintenance
0 to 40°C
Replaceable HV power supply and
Relative Humidity
ionization needle at the production
15 to 65% (with no condensation)
work site.
AC Adapters Kits
Dimensions (mm)
PERFORMANCE
86.5 L x 18 W x 50 H (Housing Only)
Output Voltage
3.0 kV AC
Weight
Approx. 80g (Housing Only)
Air Purge - Fluid
Clean Air
LED Display Indicators
Air Purge - operating pressure
0.05 to 0.6MPa
Alarm Output Signal (ALARM)
MOSFET relays
30V @ 0.3 amp contacts
Clean Check Output Signal (CC)
MOSFET relay
30V @ 0.3 amp contacts
Ozone Generation
0.05ppm or less (at a distance of
300mm from air outlet)
Ion Balance
±15 V or less at the work surface
P/N 950-C100 100mm Carrier Nozzle
P/N 950-C200 200mm Carrier Nozzle
P/N 950-C300 300mm Carrier Nozzle
P/N 950-C400 400mm Carrier Nozzle
P/N 950-C500 500mm Carrier Nozzle
P/N 950-60S Shower Nozzle
P/N 950-100B 100mm Bar Nozzle
P/N 950-200B 200mm Bar Nozzle
P/N 950-300B 300mm Bar Nozzle
P/N 950-F Flat Nozzle
P/N 950-TT Teflon Carrier Tube
Nozzle
P/N 950-ST Silicon Carrier Tube
Nozzle
P/N 950-24V-1 AC Adapter Kit
(includes power supply, signal cable
and ground wire)
P/N 950-24V-2 AC Adapter Kit
(includes power supply)
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK