Measurement and power solutions, 615 series abridged specifications – Trek 615 series High-Voltage AC-DC Generator User Manual
Page 2
www.trekinc.com
Features (cont.)
Dynamic Adjustment
Graduated 1-turn panel potentiometer is used
to optimize the AC response for various load
parameters
Current Limit/Trip
Switch selectable for either limit or trip.
Graduated 1-turn panel potentiometer is used
to adjust limit or trip level from 0 to ±50 mA
Out of Regulation
Status
Illuminates and a TTL low is provided when unit
fails to produce required HV output such as
during current limit or short circuit conditions
Trip Status
Illuminates and a TTL low is provided when the
high-voltage output is disabled due to the
output current exceeding the current trip level,
the detection of a high-voltage supply fault or
the removal of the top cover
Fault Status
A BNC provides a TTL low when the PD05034
is out of regulation for greater than 100 ms
Mechanical
Dimensions
279 mm H x 482 mm W 654 mm D
(11” H x 19” W x 25.75” D)
Weight
24.9 kg (55 lb)
HV Connector
Alden High Voltage Connector
BNC Connectors
Amplifier Input, Voltage Monitor, Current Monitor,
Remote High Voltage ON/OFF, Out of Regulation
Status, Fault/Trip Status
Operating Conditions
Temperature
0°C to 40°C (32°F to 104°F)
Relative Humidity
To 85%, noncondensing
Altitude
To 2000 meters (6561.68 ft.)
Electrical
Line Voltage
Factory Set for one of two ranges:
104 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz
AC Line Receptacle
Standard 3-prong AC line connector
Power Consumption
1000 VA, maximum
Supplied Accessories
Operators’ Manual
PN: 23340
HV Output Cable
PN: 43463
Line Cord, Spare
Fuses
PN: N5011; s
destination
elected per geographic
Optional Accessories
HV Output Cable
PN: 43463
19-in Rack Mount Kit
Model 608RA (with EIA hole spacing)
19-in Rack Mount Kit
Model 608RAJ (with JIS hole spacing)
615 Series Abridged Specifications
Performance
Output Voltage
Range
0 to ±7.5 kV DC or peak AC
Output Current
Range
0 to ±50 mA DC with a peak current capability
of ±160 for 60 µs
Input Voltage Range
0 to ±7.5 V DC or peak AC
Input Impedance
10 kW, nominal
DC Voltage Gain
1000 V/V
DC Voltage Gain
Accuracy
Better than 0.1% of full scale
DC Offset Voltage
Less than ±2 V
Output Noise
Less than 5 V rms*
Slew Rate
(10% to 90%, typical)
Greater than 1000 V/µs
Large Signal
Bandwidth
(1% distortion)
DC to greater than 15 kHz
Small Signal
Bandwidth (-3dB)
DC to greater than 75 kHz
Settling Time (to 1%)
Less than 50 µs for a 0 to 7.5 kV step
Stability
Drift with Time
Less than 50 ppm/hr, noncumulative
Drift with Temp
Less than 100 ppm/°C
Voltage Monitor
Ratio
1/1000th of the high-voltage output
DC Accuracy
Better than 0.1% of full scale
DC Offset Voltage
Less than ±2 mV
Output Noise
Less than 10 mV rms*
Output Impedance
47 W
Current Monitor
Ratio
0.05 V/ mA
DC Accuracy
Better than 1% of full scale
Offset Voltage
Less than ±10 mV
Output Noise
Less than 30 mV rms*
Bandwidth (-3dB)
DC to greater than 5 kHz
Output Impedance
47 W
Features
High-Voltage On/Off
Local
Individual push-button switch
Remote (TTL
compatible input)
TTL high (or open) turns off high-voltage output.
TTL low turns on high-voltage output.
Copyright ã 2012 TREK, INC. All specifications are subject to change. 1235DEC
*Measured using the true rms feature of the HP Model 34401A digital multimeter
Measurement and Power Solutions
TM