Measurement and power solutions, Model 601c specifications – Trek 601C High-Voltage Power Amplifier User Manual
Page 2

Features (cont.)
Digital Enable
An input providing a connection for a TTL
compatible signal to turn on and off the high-
voltage output.
Input Configuration**
Factory set as a noninverting amplifier, the
Model 601C can be configured as an inverting
amplifier.
Dynamic Adjustment
Graduated 1-turn panel potentiometer is used
to optimize the AC response for various load
parameters.
Mechanical
Dimensions
Single Channel
Instrument
222.3 mm H x 108 mm W 335 mm D
(8.75” H x 4.25” W x 13.2” D)
Double
Instrument
Channel
433.8 mm H x 108 mm W 335 mm D
(17” H x 4.25” W x 13.2” D)
Weight
Single Channel
4.3 kg (9.4 lb)
Double Channel
8.6 kg (18.8 lb)
HV Connector
SHV High Voltage Connector
Operating Conditions
Temperature
0°C to 40°C (32°F to 104°F)
Relative Humidity
To 85%, noncondensing
Altitude
To 2000 meters (6561.68 ft.)
Electrical
Line Voltage
Factory Set for one of two ranges:
90 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz
Power Consumption
150 VA, maximum
HV Cable
2 m, 66 pF per foot
Supplied Accessories
Operators’ Manual
PN: 23146
HV Output Cable
Assembly, 3 m
PN: 43874R
Line Cord
PN: N5002 (90 to 127 V AC)
Contact Factory: (80 to 250 V AC)
Optional Accessories
HV Output Cable
PN: 43874R (3 meters)
Rack Mount Kits
PN: C4036, 603RA Full Rack Mount Kit
PN: C4060, 603RA-2 Dual Instrument Rack Kit
PN: C4008, Half-Rack Mount Kit
Copyright ã 2012 TREK, INC. All specifications are subject to change. 1229/DEC
Model 601C Specifications
Performance
Output Voltage
Range
0 to ±500 V, 0 to -1 kV, or 0 to +1 kV DC or
peak AC
Output Current
Range
0 to ±10 mA DC; 0 to ±20 mA peak AC
Input Voltage Range
0 to ±10 V DC or peak AC, noninverting
Input Impedance
25 kW, nominal
DC Voltage Gain
100 V/V
(50 V/V avail. for
±500 V range only)
DC Voltage Gain
Accuracy
Better than 0.1% of full scale
DC Offset Voltage
Less than 500 mV
Output Noise
Less than 10 mV rms*
Slew Rate
(10% to 90%, typical)
Greater than 50 V/µs
Small Signal
Bandwidth (-3dB)
DC to greater than 30 kHz
Large Signal
Bandwidth
(1% distortion)
DC to greater than 8 kHz
Stability
Drift with Time
Less than 100 ppm/hr, noncumulative
Drift with Temp
Less than 50 ppm/°C
Voltage Monitor
Ratio
1/100th of the high-voltage output
DC Accuracy
Better than 0.1% of full scale
DC Offset Voltage
Less than ±5 mV
Output Noise
Less than 10 mV rms*
Output Impedance
0.1 W
Current Monitor
Ratio
0.5 V/mA
DC Accuracy
Greater than 1% of full scale
Offset Voltage
Less than ±10 mV
Output Noise
Less than 20 mV rms*
Output Impedance
0.1 W
Features
Output Voltage
Configurations
Factory set for 0 to ±500 V DC or peak AC.
Other available output voltage ranges are 0 to-1
kV or 0 to +1 kV DC or peak AC. This setting is
customer specified.
**Please specify when ordering.
*Measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter