Common Features

Power On/Off

Push-button switch

Stability

Drift with Time

Less than 600 ppm/hour, noncumulative

Drift with
Temperature

Less than 600 ppm/°C

Operating Time

Approximately 8 hours with a full battery

Hold

A momentum push-button will command the
voltage display to hold the value displayed
until the switch is released

Voltage Display Range

A 3 ½ digit liquid crystal display

Model 520

0 to ±1999 V

Model 523

0 to 19.99 kV

Resolution

Model 520

1 V

Model 523

10 V

Zero Offset

Model 520

Less than ±1 count

Model 523

Less than ±4 counts

Sampling Rate

2.5 readings per second

Power Requirements

One (1) 9-volt NEDA 1604 battery, IEC 6R61
battery or equivalent

Ground Receptacle

Snap-on connector

Operating Conditions

Temperature

15°C to 35°C

Relative Humidity

To 85%, noncondensing

Supplied Accessories

Operating Instructions (Model 520) PN: 23100

Operating Instructions (Model 523) PN: 23099

Ground Reference Cable Assembly PN: N9079

9-volt Battery PN: F1003R

Optional Accessories

Carrying Case

PN: 43469

Model 520 and 523 Specifications

Model 520 Performance

Measurement Range

0 to ±2 kV DC

Measurement
Accuracy

Model 520-2 contains an analog monitor output (1.3 mm jack) which
provides a low-voltage replica of the measured voltage.

Ratio

1/1000th of the measured voltage

Speed of Response
(10% to 90%)

Less than 25 ms for an input step change of
2 kV

Output Impedance

47 W

Model 520 Mechanical

Dimensions

31 mm H x 59 mm W x 173 mm D
(1.2” H x 2.4” W x 6.8” D)

Weight

200 g with battery
(7 oz.) with battery

Model 523 Performance

Measurement Range

0 to ±20 kV DC

Measurement
Accuracy

Model 523 Mechanical

Dimensions

31 mm H x 59 mm W x 183 mm D
(1.2” H x 2.4” W x 7.3” D)

Weight

200 g with battery
(7 oz.) with battery

Copyright © 2013 TREK, INC. All specifications are subject to change. 1332/JRB

Measurement and Power Solutions

TM

0

10

20

30

40

50

0 V

V

V x 2

520 Performance

Surface Voltage

Typical Fieldmeter

Probe-to Surface Separation (mm)

Displayed

Voltage

Model 520 Compared to Typical Fieldmeter

Displayed Voltage vs. Probe-to-Surface Separation

0

20

40

60

80

100

0 V

V

V x 2

523 Performance

Surface Voltage

Typical Fieldmeter

Probe-to Surface Separation (mm)

Displayed

Voltage

Model 523 Compared to Typical Fieldmeter

Displayed Voltage vs. Probe-to-Surface Separation

*Measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter