Trek 323 DC Stable Electrostatic Voltmeter User Manual

Page 2

background image

Performance

Features (cont.)

Features (cont.)

General

Features

Measurement Range

Probe-to-Surface Separation

Voltage Monitor Output

0 to ±100 V DC or peak AC.

1 mm to 3 mm.

A buffered 0 to ±10 V output
providing a representation of the

Response Speed Control

Sensitivity

measured voltage.

A front panel potentiometer that

5 mV.

Scale Factors

adjusts the speed/noise inter-

10:1 of the measured voltage or

relationship of the Model 323

Accuracy

20:1 of the measured voltage

AC response.

DC Accuracy

(switch selectable).

Better than 0.05% of full scale.

Output Current

Voltage Display

Voltage Monitor Output

5 mA.

3½ digit LED display.

Better than ±0.05% of full scale.

Output Impedance

Range

Voltage Display

0.1 W, nominal.

Switch selectable for ±10 V

Better than or equal to ±2 counts,

or ±100 V full scale.

referred to the voltage monitor.

Resolution

10 V Range

Speed of Response (10% to 90%)

Dimensions

0.01 V.

Less than 300 ms for a 100 V step

108 mm H x 223 mm W x 380 mm D

100 V Range

(adjustable).

(4.25" H x 8.75" W x 15" D).

0.1 V.

Zero Offset

Stability

Weight

±2 counts, referred to the

Drift with Time

3.6 kg (8 lb).

voltage monitor.

Less than 50 ppm/hour,

Sampling Rate

Voltage Monitor Connector

noncumulative.

3 readings per second.

BNC connector.

Drift with Temperature

1:1 Monitor Output

Ground Receptacle

Drift/Spacing Null Adjustment

Less than 10 mV/°C

Banana jack.

10:1 Monitor Output

AC Line Cord Receptacle

Less than 5 mV/°C

Standard three-prong line cord with

20:1 Monitor Output

integral fuse holder.

Less than 5 mV/°C

Voltage Monitor Output (1:1 ratio)

Line Supply

A buffered 0 to ±100 V output

Factory set for one of two voltage

providing a representation

ranges: 90 to 127 V AC or 180 to

Null Voltage Source

of the measured voltage.

250 V AC, at 48 to 63 Hz

A calibrated 10-turn dial representing

Scale Factor

(specify when ordering).

a 10 volt supply, with switch

1:1 of the measured voltage.

selectable polarity, used to produce

Operating Conditions

Output Noise

zero volts output when the probe is

Temperature

Less than 20 mV rms (measured

coupled to a known zero volt surface.

0 °C to 40 °C.

using the true rms feature of the

Range

Relative Humidity

Hewlett Packard Model 34401A

±10 volts

To 90%, noncondensing.

digital multimeter).

Accuracy

Output Current

1%

5 mA.

Resolution

Output Impedance

20 mV.

100 W, nominal.

This back panel adjustment minimizes
the variation in monitored voltage
values as the probe to test surface
spacing changes.

Model 10/40A Specifications

Model 323 Specifications

Copyright ã 2011 TREK, INC.
All specifications are subject to change.
1138/DEC

Model 323 Ordering Information

All specifications are with a Model 6000B-8 probe with a probe-to-surface separation of 1 mm.

Model 323 Electrostatic Voltmeter

Trek Certification

Probes

Item

Part No.

Model 323-L (90 to 127 V AC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323-L
Model 323-H (180 to 250 V AC) . . . . . . . . . . . . . . . . . . . . . . . . . . 323-H

Model 6000B-8 Probe (side-viewing, round body) . . . . . . . . . . 17054
Model 6000B-16 Probe (side-viewing, square body) . . . . . . . . 17047

TREK, INC. certifies that each Model 323 is tested and
calibrated to specifications using measurement
equipment traceable to the National Institute of
Standards and Technology or traceable to consensus
standards. A Certificate of Calibration accompanies each
instrument when it is shipped from the factory.