Factory installed standard & optional equipment – Milton CAT D50-6 50 kW Spec Sheet User Manual
Page 2
STANDBY 50 ekW 63 kVA
PRIME 45 ekW 50 kVA
60 Hz 1800 rpm 480 Volts
FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT
System
Standard
Optional
Air Inlet
• Dry replaceable paper element type with restriction indica-
tor
Cooling
• Radiator and cooling fan complete with protective guards
• Standard ambient temperatures up to 50°C (122°F)
[ ] Radiator stone guard
[ ] Radiator transition flange
Exhaust
[ ] Industrial
[ ] Residential
[ ] Critical mufflers
[ ] Overhead silencer mounting kit
Fuel
• Flexible fuel lines to base with NPT connections
[ ] Sub-base dual wall UL listed 24 hr fuel tank
[ ] Sub-base dual wall UL listed 48 hr fuel tank
[ ] Emergency vent 12ft extension
[ ] 5 gallon spill containment
Generator
• Class H insulation
• Drip proof generator air intake (NEMA 2,IP23)
• Electrical design in accordance with with BS5000
Part 99, EN61000-6, IEC60034-1, NEMA MG-1.33
• IP23 Protection
[ ] Generator upgrade 1 size
[ ] Permanent magnet excitation
[ ] Internal excitation
[ ] Anti-condensation space heater
Power Termination
• Circuit breakers, UL/CSA listed, 3 pole (100% rated)
• Power center houses EMCP controller and control termina-
tions (CB)
• Segregated low voltage wiring termination panel
• NEMA 1 steel enclosure, vibration isolated
• Electrical stub-up area directly below circuit breaker
[ ] Auxiliary contacts
[ ] Shunt trip
[ ] Overload shutdown via breaker
Governor
• Adjustable Electronic governor
Control Panels
• EMCP 4.2 digital control panel
• Vibration isolated NEMA 1 enclosure with lockable hinged
door
• DC and AC Wiring harnesses
[ ] NFPA110 upgrade
[ ] Control panel chassis
Lube
[ ] Lube oil heater
Mounting
• Heavy-duty fabricated steel base with lifting points
• Anti-vibration pads to ensure vibration isolation
• Complete OSHA guarding
• Stub-up pipe ready for connection to silencer pipework
[ ] IBC Seismic and OSHPD certification per Applicable
Building Codes: IBC2000, IBC2003, IBC2006,
IBC 2009, IBC 2012, CBC 2007, CBC 2010
Starting/Charging
• 12 volt starting motor
• Batteries with rack and cables
[ ] Battery charger – UL 10 amp
[ ] Battery disconnect switch
[ ] Battery removal (does not remove rack and cables)
[ ] Coolant Heater
General
• High gloss polyurethane paint, Caterpillar Yellow except
rails and radiators gloss black
• Anticorrosive paint protection
• All electroplated hardware
[ ] CSA Certified
[ ] Weather protective enclosure Industrial/Critical
[ ] Sound attenuated protective enclosure
[ ] Caterpillar tool set
[ ] Caterpillar White paint
2