beautypg.com

Milton CAT D125-6 125 kW Spec Sheet User Manual

Page 5

background image

LEHE5521-01

5

S T A N D B Y

1 2 5 - 1 5 0 k W

P R I M E

1 1 4 - 1 3 5 k W

6 0 H z

D125-6 (3-Phase)

Materials and specifications are subject to change without notice.

Generator Set Technical Data – 1800 rpm/60 Hz

Standby

Prime

Power Rating

kW

kVA

125

156.3

114

142.5

Lubricating System

Type: full pressure
Oil filter: spin-on, full flow
Oil cooler: watercooled
Oil type required: API CH4/CI4
Total oil capacity

L

U.S. gal

16.5

4.4

16.5

4.4

Oil pan

L

U.S. gal

15.5

4.1

15.5

4.1

Fuel System

Generator set fuel consumption
100% load

L/hr

gal/hr

40.6

10.7

36.0

9.5

75% load

L/hr

gal/hr

31.6

8.3

30.0

7.9

50% load

L/hr

gal/hr

24.5

6.5

23.2

6.1

Engine Electrical System

Voltage/ground: 12/negative
Battery charging generator ampere rating

amps

100

100

Cooling System

Water pump type: centrifugal
Radiator system capacity incl. engine

L

U.S. gal

21.0

5.5

21.0

5.5

Maximum coolant static head

m H

2

O

ft H

2

O

8.0

26.0

8.0

26.0

Coolant flow rate

L/hr

U.S. gal/hr

10 200

2,693

10 200

2,693

Minimum temperature to engine

°C

°F

85

185

85

185

Temperature rise across engine

°C

°F

7.9

14.2

7.9

14.2

Heat rejected to coolant at rated power

kW

Btu/min

74.9

4,262

69.8

3,971

Total heat radiated to room at rated power

kW

Btu/min

13.0

740

12.1

688

Radiator fan load

kW

hp

8.0

10.7

8.0

10.7

Air Requirements

Combustion air flow

m

3

/min

cfm

12.6

445

12.3

434

Maximum air cleaner restriction

kPa

in H

2

O

5

20

5

20

Radiator cooling air (zero restriction)

m

3

/min

cfm

327

11,548

327

11,548

Generator cooling air

m

3

/min

cfm

26.4

923

26.4

923

Allowable air flow restriction (after radiator)

kPa

in H

2

O

0.12

0.50

0.12

0.50

Cooling air flow (@ rated speed)

Rate with restriction

m

3

/min

cfm

317

11,195

317

11,195

Exhaust System

Maximum allowable backpressure

kPa

in Hg

15

4.4

15

4.4

Exhaust flow at rated kW

m

3

/min

cfm

29.7

1,049

28.6

1,010

Exhaust temperature at rated kW –

Dry exhaust

°C

°F

437

819

427

801

Generator Set Noise Rating*

(without attenuation) at 1 m (3 ft)

dB(A)

97

97

277/480V

266/460V

127/220V

120/240V

347/600V

Generator Technical Data

120/208V

Motor Starting Capability: (kVA)

(30% voltage dip)

Self excited

360

335

311

283

N/A

PM excited**

469

437

406

370

437

AREP excited

469

437

406

370

437

Full Load Efficiencies:

Standby

92.7

92.6

92.5

92.3

92.6

Prime

92.8

92.8

92.7

92.5

92.8

Reactances (per unit):

X

d

2.74

2.99

3.27

3.65

2.99

X'

d

0.10

0.10

0.11

0.13

0.10

X"

d

0.057

0.062

0.068

0.076

0.062

X

q

1.65

1.79

1.96

2.19

1.79

X"

q

0.068

0.074

0.080

0.090

0.074

X

2

0.063

0.068

0.075

0.083

0.068

X

0

0.004

0.005

0.005

0.006

0.005

Time Constants:

t'

d

t"

d

t'

do

t

a

100 ms

10 ms

2865 ms

15 ms

* dB(A) levels are for guidance only

** With PMG Excited Option AVR12

Reactances

shown are

applicable to the

standby rating.

This manual is related to the following products: