beautypg.com

Technical data – Milton CAT G3516 1800 rpm 1300 kW 60 Hz Spec Sheet User Manual

Page 4

background image

C O N T I N U O U S

1 3 0 0 e k W
1 4 0 0 e k W

6 0 H z

LEHE2033-01

4

TECHNICAL DATA

*

*Assumes synchronous driver.

**Emissions data measurements are consistent with those described in EPA CFR 40 Part 89 Subpart D & E and ISO8178-1 for

measuring HC, CO, PM, NOx. Data shown is based on steady state engine operating conditions of 25° C (77° F), 96.28 kPa
(28.43 inches Hg) and fuel having a LHV of 35.6 mJ/N•m

3

(905 Btu/cu.ft) at 101.60 kPa (30.00 inches Hg) absolute and 0° C (32° F).

Not to exceed emission data shown is subject to instrumentation, measurement, facility and engine fuel system adjustments.

Generator Set — 1800 rpm/60 Hz/480 Volts

DM5497

DM5495

G3516B LE Gas Generator Set

Emission level (NOx)

g/bhp-hr

1.0

1.0

Aftercooler — SCAC temperature

Deg C

Deg F

32

90

54

130

Package Performance

Power rating @ 1.0 pf (unity)

ekW

1410

1310

Power rating @ 0.8 pf (3)

ekW

1400

1300

kVA

1750

1625

Fuel Consumption (1)

100% load 60 without fan

N•m

3

/hr

scf/hr

396

14,770

369

13,789

75% load 60 without fan

N•m

3

/hr

scf/hr

312

11,650

288

10,737

50% load 60 without fan

N•m

3

/hr

scf/hr

223

8321

208

7777

Electrical Efficiency

%

36.3

35.7

Altitude Capability (2)

At 25° C/77° F ambient

M

ft

872

2862

903

2961

Cooling System

Ambient air temperature

Deg C

Deg F

25

77

25

77

Jacket water temperature (maximum outlet)

Deg C

Deg F

92

198

92

198

Exhaust System

Combustion air inlet flow rate

N•m

3

/min

scfm

110

4117

105

3926

Exhaust stack gas temperature

Deg C

Deg F

532

990

530

986

Exhaust gas flow rate

N•m

3

/min

cfm

342

12,064

325

11,469

Exhaust flange size (internal diameter)

mm

in

203

8

203

8

Heat Balance (2) (3)

Low Heat Value (LHV) fuel input

kW

Btu/min

4032

229,357

3764

214,100

Heat rejection to jacket water (total)

kW

Btu/min

783

45,511

764

43,448

Heat rejection to exhaust (LHV to 350° F)

kW

Btu/min

958

54,471

906

51,547

Heat rejection to A/C — Stage 2

kW

Btu/min

180

10,211

118

6717

Heat rejection to atmosphere from engine

kW

Btu/min

137

7793

136

7762

Heat rejection to atmosphere from generator

kW

Btu/min

44

2523

43

2432

Alternator

Motor starting capability @ 30% voltage dip*

KVA

3271

2661

Frame

824

697

Temperature rise

Deg C

105

105

Lube System

Lube oil refill volume w/filter change for standard sump

L

Gal

401

106

401

106

Emissions**

NOx

g/ghp-hr

1.0

1.0

CO

g/ghp-hr

2.5

2.6

HC (total)

g/ghp-hr

4.1

4.4

HC (non-methane)

g/ghp-hr

0.62

0.66

Exhaust O

2

(dry)

%

8.9

9.2