beautypg.com

Technical data, Rating definitions and conditions – Milton CAT G3516 1800 rpm 1300 kW 60 Hz Spec Sheet User Manual

Page 3

background image

C O N T I N U O U S

1 3 0 0 e k W
1 4 0 0 e k W

6 0 H z

TECHNICAL DATA

*

*Assumes synchronous driver.

**Emissions data measurements are consistent with those described in EPA CFR 40 Part 89 Subpart D & E and ISO8178-1 for

measuring HC, CO, PM, NOx. Data shown is based on steady state engine operating conditions of 25° C (77° F), 96.28 kPa
(28.43 inches Hg) and fuel having a LHV of 35.6 mJ/N•m

3

(905 Btu/cu.ft) at 101.60 kPa (30.00 inches Hg) absolute and 0° C (32° F).

Not to exceed emission data shown is subject to instrumentation, measurement, facility and engine fuel system adjustments.

LEHE2033-01

3

Generator Set — 1800 rpm/60 Hz/480 Volts

DM5498

DM5496

G3516B LE Gas Generator Set

Emission level (NOx)

g/bhp-hr

0.5

0.5

Aftercooler — SCAC temperature

Deg C

Deg F

32

90

54

130

Package Performance

Power rating @ 1.0 pf (unity)

ekW

1410

1310

Power rating @ 0.8 pf (3)

ekW

1400

1300

kVA

1750

1625

Fuel Consumption (1)

100% load 60 without fan

N•m

3

/hr

scf/hr

407

15,190

380

14,174

75% load 60 without fan

N•m

3

/hr

scf/hr

319

11,912

298

11,134

50% load 60 without fan

N•m

3

/hr

scf/hr

229

8525

211

7879

Electrical Efficiency

%

35.3

34.8

Altitude Capability (2)

At 25° C/77° F ambient

M

ft

553

1813

682

2237

Cooling System

Ambient air temperature

Deg C

Deg F

25

77

25

77

Jacket water temperature (maximum outlet)

Deg C

Deg F

92

198

92

198

Exhaust System

Combustion air inlet flow rate

N•m

3

/min

scfm

115

4290

110

4120

Exhaust stack gas temperature

Deg C

Deg F

529

985

523

974

Exhaust gas flow rate

N•m

3

/min

cfm

355

12,525

338

11,923

Exhaust flange size (internal diameter)

mm

in

203

8

203

8

Heat Balance (2) (3)

Low Heat Value (LHV) fuel input

kW

Btu/min

4146

235,819

3868

220,033

Heat rejection to jacket water (total)

kW

Btu/min

826

46,996

798

45,398

Heat rejection to exhaust (LHV to 350° F)

kW

Btu/min

989

56,262

930

52,907

Heat rejection to A/C — Stage 2

kW

Btu/min

193

10,956

133

7542

Heat rejection to atmosphere from engine

kW

Btu/min

138

7838

137

7794

Heat rejection to atmosphere from generator

kW

Btu/min

44

2513

43

2432

Alternator

Motor starting capability @ 30% voltage dip*

KVA

3271

2661

Frame

824

697

Temperature rise

Deg C

105

105

Lube System

Lube oil refill volume w/filter change for standard sump

L

Gal

401

106

401

106

Emissions**

NOx

g/ghp-hr

0.5

0.5

CO

g/ghp-hr

2.4

2.5

HC (total)

g/ghp-hr

4.8

5.4

HC (non-methane)

g/ghp-hr

0.72

0.81

Exhaust O

2

(dry)

%

9.1

9.2

Continuous — Output available without varying load for an
unlimited time.

(1) Ratings and fuel consumption are based on ISO3046/1
standard reference conditions of 25° C (77° F) and 100 kPa
(29.61 inches Hg).

(2) Ratings and fuel consumption based on ISO3046/1
conditions with nominal 2.5 kPa inlet restriction and 5 kPa
exhaust restriction. All performance numbers listed on this
page are at these conditions except Fuel input (1) .

(3) Ratings are based on pipeline natural gas having a LHV
(low heat value) of 35.6 mJ/N•m

3

(905 Btu/cu.ft) and 80 MN.

For values in excess of the altitude, temperature, inlet/exhaust
restriction, or for natural gas compositions different from the
conditions listed, contact your local Caterpillar dealer.

RATING DEFINITIONS AND CONDITIONS