Factory installed standard & optional equipment – Milton CAT 3512C 1500 kW 1875 kVA 60 Hz 1800 rpm 480 Volts Spec Sheet User Manual
Page 2

®
STANDBY 1500 ekW 1875 kVA
60 Hz 1800 rpm 480 Volts
FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT
System
Standard
Optional
Air Inlet
• Single element canister type air cleaner with service
indicator
• Dual element & heavy duty air cleaners (with
pre-cleaners)
• Air inlet adapters & shutoff
Cooling
• EPA Tier II Certified Std PGS provides ATAAC
• All 3512C package radiators shipped installed
• Air return temp from ATAAC 50ºC 122ºF) at 30ºC
(86ºC)ambient temperature.
• Radiator fan and fan drive
• Fan and belt guards
• Coolant drain line with valve
• Coolant level sensors*
• Caterpillar Extended Life Coolant*
• Radiator removal
• Coolant level switch gauge
• Heat exchanger and expansion tank
Exhaust
• Exhaust manifold - dry - dual - 8 in
• 203 mm (8 in) ID round flanged outlet
• Mufflers
• Stainless steel exhaust flex fittings
• Elbows, flanges, expanders & Y adapters
Fuel
• Secondary fuel filters
• Fuel cooler*
• Fuel priming pump
• Flexible fuel lines-shipped loose
• Duplex secondary fuel filter
• Primary fuel filter with fuel water separator
*Not included with packages without radiator
Generator
• Class H insulation
• CAT digital voltage regulator (CDVR) with DVAR/PF
control, 3-phase sensing
• Winding temperature detectors
• Anti-condensation space heaters
• Reactive droop
• Oversize & premium generators
Power Termination
•Bus bar (NEMA and IEC mechanical lug holes)- right
side standard
•Top and bottom cable entry
• Circuit breakers, UL listed, 3 pole shunt trip, 100%
rated, choice of trip units, manual or electrically
operated (low voltage only)
• Circuit breakers, IEC compliant, 3 or 4 pole with shunt
trip (low voltage only), choice of trip units, manual or
electrically operated
• Shroud cover for bottom cable entry
• Power terminations can be located on the left and/or
rear as an option. Also, multiple circuit breakers can
be ordered (up to 2)
Governor
• ADEM™ III
• Load share module
Control Panel
• User interface panel (UIP) - rear mount
• EMCP 3.1 Genset Controller
• Speed Adjust
• AC & DC customer wiring area (right side)
• Emergency Stop Pushbutton
• EMCP 3.3
• Option for right or left mount UIP
• Option for rear or left mount Customer wiring area
• Local & remote annunciator modules
• Load share module
• Discrete I/O Module
• Generator temperature monitoring & protection
• Voltage Adjust
Lube
• Lubricating oil
• Gear type lube oil pump
• Integral lube oil cooler
• Oil filter, filler and dipstick
• Oil drain line and valve
• Fumes disposal
• Oil level regulator
• Deep sump oil pan
• Electric & air prelube pumps
• Manual prelube with sump pump
• Duplex oil filter
Mounting
• Rails - engine / generator / radiator mounting
• Anti-vibration mounts (shipped loose)
• Rubber anti-vibration mounts (shipped loose)
• Isolator removal
• Spring type vibration isolator
Starting/Charging
• 24 volt starting motor(s)
• Batteries with rack and cables
• Battery disconnect switch
• Battery chargers (10 &20 Amp)
• 45 amp charging alternator
• Oversize batteries
• Ether starting aids
• Heavy duty starting motors
• Barring device (manual)
• Air starting motor with control & silencer