beautypg.com

70cru02 – Vishay 70CRU02 User Manual

Page 4

background image

70CRU02

Bulletin PD-20619 rev. C 12/06

Fig. 5 - Max. Allowable Case Temperature

Vs. Average Forward Current

Fig. 8 - Typical Stored Charge vs. di

F

/dt

Fig. 6 - Forward Power Loss Characteristics

(3)

Formula used: T

C

= T

J

- (Pd + Pd

REV

) x R

thJC

;

Pd = Forward Power Loss = I

F(AV)

x V

FM

@ (I

F(AV)

/

D) (see Fig. 6);

Pd

REV

= Inverse Power Loss = V

R1

x I

R

(1 - D); I

R

@ V

R1

= rated V

R

Average Forward Current - I

F(AV)

(A)

Fig. 7 - Typical Reverse Recovery vs. di

F

/dt

Allowable Case Temperature (°C)

Average Power Loss ( W )

trr ( ns )

Qrr ( nC )

di

F

/dt (A/μs )

di

F

/dt (A/μs )

80

90

100

110

120

130

140

150

160

170

180

0

10

20

30

40

50

60

DC

Square wave (D = 0.50)
Rated Vr applied

see note (3)

0

10

20

30

40

50

0

10

20

30

40

50

60

RMS Limit

D = 0.20
D = 0.25
D = 0.33
D = 0.50
D = 0.75
DC

0

10

20

30

40

50

60

70

80

100

1000

If = 35A
Vrr = 100V

Tj = 125˚C

Tj = 25˚C

0

100

200

300

400

500

600

100

1000

If = 35A
Vrr = 100V

Tj = 125˚C

Tj = 25˚C

Average Forward Current - I

F(AV)

(A)

Document Number: 93022

www.vishay.com

4