Altronix NetWay1 Installation Instructions User Manual
Page 4

- 4 -
NetWay1
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.
IINetWay1
L12L
MEMBER
Maintenance:
Unit should be tested at least once a year for the proper operation as follows:
While the NetWay1 is powered and the output is connected to a suitable UL Listed PoE device.
The NetWay1 should be tested for PoE shutdown operation (For UL 60950-1 applications only).
For UL294 applications, the NetWay1 is to be tested as part of a complete Access Control System and in accordance
with listed Access Control Devices.
Troubleshooting:
Refer to NetWay1 Port Status and LED Flash Codes pg. 2.
Technical Specifications:
Parameter
Description
No. of Ports
One (1)
Input power requirements
24VAC @ 1.2 amp (min. 30VA transformer, For UL 60950-1 applications only)
or 24VDC @ 1.2 amp.
Indicators
Port Status LED
PoE Shutdown Voltage
and Current Range
5VDC to 24VDC or 12VAC to 24VAC
Maximum current: 2mA for 5VDC
Maximum current for higher voltages: 10mA
Environmental Conditions Operating Ambient Temperature: UL60950-1 - 32ºF to 104ºF (0ºC to 40ºC).
UL294 - 32ºF to 120.2ºF (0ºC to 49ºC).
Relative humidity: 85%, +/ --- 5%
Storage Temperature: --- 4º to 158ºF (--- 20º to 70ºC) Storage
Operating Altitude: --- 1000 to 10,000 ft. (--- 304.8 to 3048m).
Regulatory Compliance
UL/CUL Listed for Information Technology Equipment (UL 60950-1).
UL Listed for Access Control Systems (UL294).
Power over Ethernet (PoE) for Access Control (UL294B).
CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment.
CE approved