Table 11: characteristics power supply, See table 11 f, Confidential / released – Siemens TC35i User Manual
Page 30
TC35i Terminal Hardware Interface Description
Confidential / Released
TC35i_T_HD_v01.05 Page
30/37
10.07.2003
Table 11: Characteristics power supply
Parameter
Description
Conditions
Min Typ
Max
Unit
V
PLUS
Allowed voltage ripple
(peak-peak), drop
during transmit burst
peak current
Talk Mode, power control
level for P
out
max
1)
1
V
@8V
480
550
@12V
700
800
Power Down
mode
@30V
1750
1850
µA
@8V
45
@12V
30
SLEEP mode
@30V
17
mA
@8V
70
@12V
50
NET Searching
mode
@30V
30
mA
@8V
60
@12V
45
IDLE mode
@30V
25
mA
@8V
270
560
@12V
170
330
Average supply current
(average time 3 min.)
TALK mode
(max. current
@GSM 900,
Power Level 5)
@30V
72
125
mA
@8V
1.7
3.2
@12V
1.2
2.4
I
PLUS
2)
Peak supply current
(during 577µs
transmission slot every
4.6ms)
Power control
level for Pout
max
@30V
0.7
1.2
A
Allowed powerfail time
without terminal reset
or power down
After this time the Terminal
will be reset or switched off
1
ms
t
PLUS-Fail
Allowed powerfail time
without RTC (real time
clock) reset
After this time the RTC will
be reset
7
s
t
R_PLUS
Allowed rise time of
V
PLUS
0% to 100%
20
ms
LE
Cable
Length of supply cable
3
m
1)
Lowest voltage (minimum peak) incl. all ripple and drops >7.6V including voltage drop, ripple and
spikes, measured at western jack (6-pole) pin (1 to 6)
2)
Typical values measured with antenna impedance = 50 Ohm (return loss >20dB)
Maximum values measured with mismatched antenna