Electrical and environmental characteristics, 5 electrical and environmental characteristics, Confidential / released – Siemens TC35i User Manual
Page 29
TC35i Terminal Hardware Interface Description
Confidential / Released
TC35i_T_HD_v01.05 Page
29/37
10.07.2003
5 Electrical and environmental characteristics
Table 9: Absolute maximum ratings
Parameter
Port / Description
Min.
Max.
Unit
Supply voltage
PLUS
-50
30
V
Overvoltage
PLUS / for 1h
33
V
Input voltage for on/off
Control lines
/IGT_IN, /PD_IN
-5
30
V
/TXD, /DTR, /RTS
-30
+30
V
RS-232 input voltage range
/RXD, /CTS, /DSR, /DCD, /RING
-0.3
+5.3
V
Microphone input line
voltage
MICP, MICN
-0.3
+10
V
Earpiece input voltage
EPP, EPN
-0.3
+3.3
V
Immunity against discharge
of static electricity
all connectors (lines)
-8
+8
kV
Protection Class
IP40
(avoid exposing TC35i Terminal to
liquid or moisture, for example do not use it
in a shower or bath)
IP 40
Mechanical vibrations
amplitude
@ 5-200Hz
7.5
mm
Mechanical pulse-
acceleration
@ 18 ms duration
30
g
Table 10: Operating conditions
Parameter
Min
Typ
Max
Unit
Ambient temperature
-20
25
55
°C
Supply voltage PLUS
measured at (6-pole)
western jack plug (1 to 6)
7.6 lowest voltage
(minimum peak) incl. all
ripple and drops
12
30
V