Typical applications are overfill and dry run protection. With an
operating distance of 100 m, VEGAMIP 62 can be used, for example,
in bulk solids silos with large diameters. Thanks to its simple and
rugged measuring system, VEGAMIP 62 is virtually unaffected by the
process and the chemical and physical properties of the medium.
VEGAMIP
62 can also be used for detection of vehicles and ships or
for material recognition on conveyor belts.
It works even under extremely difficult conditions, such as different
granulation sizes, contamination, extreme filling noise, high temper-
atures, strong dust generation or abrasive products.
The VEGAMIP consists of an emitting unit VEGAMIP T61 and a
receiving unit VEGAMIP R62 with external housing.
4
4
6
6
2
3
1
4
5
7
8
Fig. 1: VEGAMIP 62 with plastic housing
1
Emitting unit VEGAMIP T61
2
Receiving unit VEGAMIP R62
3
External housing - VEGAMIP R62 (processing unit)
4
Housing cover
5
Housing with control electronics
6
Process fitting
7
Socket
8
Wall mounting plate
8
VEGAMIP R
62 • - Transistor
3 Product description
41911
-EN
-120228
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)