VEGA VEGAMIP R62 Receiving unit - Transistor User Manual
Page 40
Switching delay
adjustable from 0.1 … 20 s (on/off)
Min. distance
100 mm (3.94 in)
Ambient conditions
Ambient, storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Measured variable
Limit level of bulk solids and liquids
Process pressure
3)
-
VEGAMIP
62, threaded version - internal
horn antenna with PTFE cover
-1 … 4 bar/-100 … 400 kPa (-14.5 … 58 psig)
-
VEGAMIP
62, plastic encapsulated an-
tenna with PP cover
-1 … 2 bar/-100 … 200 kPa (-14.5 … 29 psig)
-
VEGAMIP
62, horn antenna/316L
-1 … 40 bar/-100 … 4000 kPa (-14.5 … 580 psig)
-
VEGAMIP
62, encapsulated horn anten-
na with PTFE cover
-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)
-
VEGAMIP
62 with mounting adapter
unpressurized (IP 67)
Process temperature (thread or flange tem-
perature)
-
VEGAMIP
62, threaded version - internal
horn antenna with PTFE cover
-40 … +80 °C (-40 … +176 °F)
-
VEGAMIP
62, plastic encapsulated an-
tenna with PP cover
-40 … +80 °C (-40 … +176 °F)
-
VEGAMIP
62, horn antenna/316L - seal:
FKM (SHS FDM 70C3 GLT)
-40 … +130 °C (-40 … +266 °F)
-
VEGAMIP
62, horn antenna/316L - seal:
FFKM (Kalrez 6375)
-20 … +130 °C (-4 … +266 °F)
-
VEGAMIP
62, encapsulated horn anten-
na with PTFE cover
-40 … +200 °C (-40 … +392 °F)
-
VEGAMIP
62 with mounting adapter
150 mm (optional)
-40 … +250 °C (-40 … +482 °F)
-
VEGAMIP
62 with mounting adapter
300 mm (optional)
-40 … +450 °C (-40 … +842 °F)
Electromechanical data
Cable entry/plug
4)
- instrument housing
-
Single chamber housing
l
1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; attached 1 x cable
entry M20 x 1.5
or:
3)
Note max. pressure of the process fitting
4)
depending on the version
40
VEGAMIP R
62 • - Transistor
9 Supplement
41911
-EN
-120228