beautypg.com

VEGA VEGAMIP R62 Receiving unit - Transistor User Manual

Page 40

background image

Switching delay

adjustable from 0.1 … 20 s (on/off)

Min. distance

100 mm (3.94 in)

Ambient conditions

Ambient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

Measured variable

Limit level of bulk solids and liquids

Process pressure

3)

-

VEGAMIP

62, threaded version - internal

horn antenna with PTFE cover

-1 … 4 bar/-100 … 400 kPa (-14.5 … 58 psig)

-

VEGAMIP

62, plastic encapsulated an-

tenna with PP cover

-1 … 2 bar/-100 … 200 kPa (-14.5 … 29 psig)

-

VEGAMIP

62, horn antenna/316L

-1 … 40 bar/-100 … 4000 kPa (-14.5 … 580 psig)

-

VEGAMIP

62, encapsulated horn anten-

na with PTFE cover

-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psig)

-

VEGAMIP

62 with mounting adapter

unpressurized (IP 67)

Process temperature (thread or flange tem-
perature)

-

VEGAMIP

62, threaded version - internal

horn antenna with PTFE cover

-40 … +80 °C (-40 … +176 °F)

-

VEGAMIP

62, plastic encapsulated an-

tenna with PP cover

-40 … +80 °C (-40 … +176 °F)

-

VEGAMIP

62, horn antenna/316L - seal:

FKM (SHS FDM 70C3 GLT)

-40 … +130 °C (-40 … +266 °F)

-

VEGAMIP

62, horn antenna/316L - seal:

FFKM (Kalrez 6375)

-20 … +130 °C (-4 … +266 °F)

-

VEGAMIP

62, encapsulated horn anten-

na with PTFE cover

-40 … +200 °C (-40 … +392 °F)

-

VEGAMIP

62 with mounting adapter

150 mm (optional)

-40 … +250 °C (-40 … +482 °F)

-

VEGAMIP

62 with mounting adapter

300 mm (optional)

-40 … +450 °C (-40 … +842 °F)

Electromechanical data

Cable entry/plug

4)

- instrument housing

-

Single chamber housing

l

1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; attached 1 x cable
entry M20 x 1.5

or:

3)

Note max. pressure of the process fitting

4)

depending on the version

40

VEGAMIP R

62 • - Transistor

9 Supplement

41911

-EN

-120228