11 Supplement

VEGAPULS 67 • Modbus and Levelmaster protocol

41369-EN-121011

Ambient conditions
Ambient, storage and transport tempera-

ture

-40 … +80 °C (-40 … +176 °F)

Process conditions
Process temperature (measured on the

process fitting)

-40 … +80 °C (-40 … +176 °F)

Vessel pressure

-1 … 2 bar (-100 … 200 kPa/-14.5 … 29.0 psig)

Vessel pressure - version with adapter

flange from DN 150 PP

-1 … 1 bar (-100 … 100 kPa/-14.5 … 14.5 psig)

Vibration resistance

4)

Ʋ Plastic horn antenna with compres-

sion or adapter flange

mechanical vibrations up to 2 g in the frequency range

5 … 200 Hz

Ʋ Plastic horn antenna with mounting

strap

mechanical vibrations up to 1 g in the frequency range

5 … 200 Hz

Electromechanical data - version IP 66/IP 67
Options of the cable entry

Ʋ Cable gland

M20 x 1.5 (cable: ø 5 … 9 mm)

Ʋ Cable entry

½ NPT

Ʋ Blind stopper

M20 x 1.5; ½ NPT

Ʋ Closing cap

M20 x 1.5; ½ NPT

Plug options

Ʋ Supply and signal circuit (only with low

voltage)

M12 x 1

Ʋ Indication circuit

M12 x 1

Wire cross-section (spring-loaded terminals)

Ʋ Massive wire, cord

0.2 … 2.5 mm² (AWG 24 … 14)

Ʋ Stranded wire with end sleeve

0.2 … 1.5 mm² (AWG 24 … 16)

Indicating and adjustment module
Voltage supply and data transmission

through the sensor

Indication

LC display in dot matrix

Measured value indication

Ʋ Number of digits

5

Ʋ Size of digits

W x H = 7 x 13 mm

Adjustment elements

4 keys

Protection rating

Ʋ unassembled

IP 20

Ʋ mounted into the sensor without cover IP 40

Materials

Ʋ Housing

ABS

Ʋ Inspection window

Polyester foil

4)

Tested according to the guidelines of German Lloyd, GL directive 2.