beautypg.com

11 supplement, 1 technical data – VEGA VEGAPULS 67 (≥ 2.0.0 - ≥ 4.0.0) Modbus and Levelmaster protocol User Manual

Page 59

background image

59

11 Supplement

VEGAPULS 67 • Modbus and Levelmaster protocol

41369-EN-121011

11 Supplement

11.1 Technical data

General data
316L corresponds to 1.4404 or 1.4435
Materials, wetted parts

Ʋ Adapter flange

PP

Ʋ Seal, adapter flange

FKM (COG VI500), EPDM (COG AP310)

Ʋ Antenna

PBT-GF 30

Ʋ Focussing lense

PP

Materials, non-wetted parts

Ʋ Compression flange

PP

Ʋ Mounting strap

316L

Ʋ Fixing screws, mounting strap

316L

Ʋ Fixing screws, adapter flange

304

Ʋ Plastic housing

plastic PBT (Polyester)

Ʋ Aluminium die-casting housing

Aluminium die-casting AlSi10Mg, powder-coated - basis:

Polyester

Ʋ Stainless steel housing

316L

Ʋ Seal between housing and housing

cover

NBR (stainless steel housing, precision casting), silicone

(aluminium/plastic housing; stainless steel housng,

electropolished)

Ʋ Inspection window in housing cover

(optional)

Polycarbonate

Ʋ Ground terminal

316L

Process fittings

Ʋ Flanges

DIN from DN 80, ANSI from 3", JIS from DN 100 10K

Weight depending on process fitting and

housing material

0.7 … 3.4 kg (1.543 … 7.496 lbs)

Max. torque, mounting screws - strap on

the sensor housing

4 Nm

Max. torque flange screws

Ʋ Compression flange DN 80

5 Nm (3.689 lbf ft)

Ʋ Adapter flange DN 100

7 Nm (5.163 lbf ft)

Max. torque for NPT cable glands and Conduit tubes

Ʋ Plastic housing

10 Nm (7.376 lbf ft)

Ʋ Aluminium/Stainless steel housing

50 Nm (36.88 lbf ft)

Input variable
Measured variable

The measured variable is the distance between the pro-

cess fitting of the sensor and the product surface. The

reference plane is the seal surface of the flange.