3 Product description

VEGADIF 65 • Foundation Fieldbus

36130-EN-130417

via a Linking device with HSE (High speed Ethernet) and addi-

tional power supply according to IEC 61158-2

The DD (Device Descriptions) and CFF (capability files) necessary

for planning and configuration of your FF (Foundation Fieldbus) com-

munication network are available in the download area of the VEGA

homepage www.vega.com under "Services - Downloads - Software

- Foundation Fieldbus". The appropriate certificates are also available

there. A CD with the appropriate files and certificates can be ordered

via e-mail under [email protected] or by phone from one of the

VEGA agencies under the order number "DRIVER.S".
The backlight of the display and adjustment module is powered by the

sensor. Prerequisite is a certain level of operating voltage.
The data for power supply are specified in chapter "Technical data".
The optional heating requires its own operating voltage. You can find

details in the supplementary instructions manual "Heating for display

and adjustment module".
This function is generally not available for approved instruments.

3.3 Operation

The instrument can be adjusted with the following adjustment media:

With the display and adjustment module

with the suitable VEGA DTM in conjunction with an adjustment

software according to the FDT/DTM standard, e.g. PACTware and

PC

a configuration tool

3.4 Packaging, transport and storage

Your instrument was protected by packaging during transport. Its

capacity to handle normal loads during transport is assured by a test

based on ISO 4180.
The packaging of standard instruments consists of environment-

friendly, recyclable cardboard. For special versions, PE foam or PE

foil is also used. Dispose of the packaging material via specialised

recycling companies.
Caution:

Instruments for oxygen applications are sealed in PE foil and provided

with a label "Oxygen! Use no Oil". Remove this foil just before mount-

ing the instrument! See instruction under "Mounting".

Transport must be carried out under consideration of the notes on the

transport packaging. Nonobservance of these instructions can cause

damage to the device.

The delivery must be checked for completeness and possible transit

damage immediately at receipt. Ascertained transit damage or con-

cealed defects must be appropriately dealt with.

DD/CFF

Packaging

Transport

Transport inspection