beautypg.com

1 product description, 1 function and configuration, 2 self-monitoring – VEGA VEGABAR 40 HART User Manual

Page 4

background image

4

VEGABAR 40 (HART

®

)

Product description

1 Product description

1.1 Function and configuration

VEGABAR 40 process pressure transmitters
are efficient instruments for process pres-
sure measurement. As pressure sensor
element, the dry ceramic-capacitive measur-
ing cell CERTEC

®

is used. The process pres-

sure causes a capacitance change within the
measuring cell via the diaphragm. This ca-
pacitance change is detected by an ASIC
(Application specific integrated circuit) and
converted into a pressure proportional signal
by the integrated sensor electronics with
microcontroller. Precise, high-resolution dig-
ital processing of measured data ensures
excellent technical data.

The electronics module is powered by a
separate VEGA signal conditioning instru-
ment, a stabilised power supply unit or a PLC
(active input). After the adjustment, a stand-
ardised 4 … 20 mA current signal is made
available which can be displayed (e.g. in
PLC systems) or further processed.

For carrying out adjustment, the following
alternatives are available:
- adjustment module directly on VEGABAR
- adjustment module in external housing

(VEGADIS 10)

- via PC with adjustment software VEGA

Visual Operating (VVO)

- with HART

®

handheld

1.2 Self-monitoring

To improve reliability, the functionality of im-
portant electronic components is constantly
checked, and internal parameters such as
sensor value, temperature and operating
voltage are closely monitored.

VEGABAR 40 with ceramic CERTEC

®

measur-

ing cell offers the advantage of continuous
self-monitoring. The measuring and reference
capacitances of the measuring cell have a
predefined correlation to each other over the
entire measuring range. Any deviation from
these data is a reliable indicator of a malfunc-
tion of the measuring cell.

If errors or malfunctions are detected during
these routines, the fault signal is triggered via
the 4 … 20 mA output (current jump to
3,6 mA or 22 mA).