VEGA VEGACAP 82-98 User Manual
Page 8
8
VEGACAP
Function
Modes
A/B mode
A - max. detection or overfill protection
B - min. detection or dry run protection
Integration time
approx. 0.5 sec
Signal lamp
LED for indication of the switching mode
Test switch (option)
switching point simulation
(not VEGACAP 27, 35, 98)
CE conformity
VEGACAP compact level switches meet the protective regulations of EMC (89/336/EWG)
and NSR (73/23/EWG). The conformity has been judged acc. to the following standards:
EMC
Emission
EN 50 081 - 1: 1992
Susceptibility
EN 50 082 - 1: 1992
NSR
EN 61 010 - 1: 1993
CE conformity (VEGACAP 27, 35, 98)
VEGACAP 27, 35 and 98 compact level switches meet the protective regulations of EMC
(89/336/EWG) and NSR (73/23/EWG). The conformity has been judged acc. to the following
standards:
EMC
Emission
EN 50 081 - 1: 1992
Susceptibility
EN 50 082 - 2: 1995
NSR
EN 61 010 - 1: 1993
Oscillators
General (CAP E30 R, C, T)
Frequency
400 kHz
Capacitance range
- range 1
0 … 20 pF
sensitive
- range 2
0 … 85 pF
…
- range 3
0 … 450 pF
insensitive
Switching hysteresis
approx. 2 % relating to the adjusted
capacitance value
Terminals
max. 1.5 mm
2
wire cross-section
C - Non-contact switch (CAP E30 C)
Supply voltage
20 … 250 V AC, 50/60 Hz
20 … 250 V DC
Output
non-contact switch
Domestic current requirement
< 5 mA (via the load circuit)
for reliable switching off of contactors with very
low holding current, the domestic current is
briefly lowered below 1 mA.
Load current
min. 10 mA, max. 400 mA (4 A for 40 ms)
at a load current of more than 300 mA the
max. permissible ambient temperature is 60°C.
Protection class
I
Overvoltage category
III
Product description