beautypg.com

VEGA VEGACAP 82-98 User Manual

Page 8

background image

8

VEGACAP

Function

Modes

A/B mode
A - max. detection or overfill protection
B - min. detection or dry run protection

Integration time

approx. 0.5 sec

Signal lamp

LED for indication of the switching mode

Test switch (option)

switching point simulation
(not VEGACAP 27, 35, 98)

CE conformity

VEGACAP compact level switches meet the protective regulations of EMC (89/336/EWG)
and NSR (73/23/EWG). The conformity has been judged acc. to the following standards:
EMC

Emission

EN 50 081 - 1: 1992

Susceptibility

EN 50 082 - 1: 1992

NSR

EN 61 010 - 1: 1993

CE conformity (VEGACAP 27, 35, 98)

VEGACAP 27, 35 and 98 compact level switches meet the protective regulations of EMC
(89/336/EWG) and NSR (73/23/EWG). The conformity has been judged acc. to the following
standards:
EMC

Emission

EN 50 081 - 1: 1992

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993

Oscillators

General (CAP E30 R, C, T)

Frequency

400 kHz

Capacitance range
- range 1

0 … 20 pF

sensitive

- range 2

0 … 85 pF

- range 3

0 … 450 pF

insensitive

Switching hysteresis

approx. 2 % relating to the adjusted
capacitance value

Terminals

max. 1.5 mm

2

wire cross-section

C - Non-contact switch (CAP E30 C)

Supply voltage

20 … 250 V AC, 50/60 Hz

20 … 250 V DC

Output

non-contact switch

Domestic current requirement

< 5 mA (via the load circuit)

for reliable switching off of contactors with very
low holding current, the domestic current is
briefly lowered below 1 mA.

Load current

min. 10 mA, max. 400 mA (4 A for 40 ms)

at a load current of more than 300 mA the
max. permissible ambient temperature is 60°C.

Protection class

I

Overvoltage category

III

Product description