Instruments with stex approval, Product description, High-temperature electrode – VEGA VEGACAP 82-98 User Manual
Page 15
VEGACAP
15
0
-50
200
10
400 °C
bar
-10
100
300
Product description
8
7
0
-30
100
16
˚C
bar
0
-30
60
80
16
˚C
bar
VEGACAP 34, 97, 98
unpressurized
Mechanical connection, Aluminium
(VEGACAP 97, 98: PP)
Isolation
VEGACAP
11
-
7
8
-
-
21
7
-
8
-
8
26
-
-
8
-
8
27
-
-
8
-
8
31
-
7
8
-
-
33
-
-
8
-
-
34 unpressurized
-
-
-
7
-
35
-
-
-
7
-
42
-
-
8
-
-
52
-
-
8
-
-
53
-
-
-
7
-
82 unpressurized
-
-
9
-
-
84 unpressurized
92
-
-
9
-
-
97
-
7
-
-
-
98
-
7
-
-
-
High-temperature electrode
Isolation
VEGACAP
60
11
61
11
PE
PP
PTFE
PE/PA 12
PFA
1)
Temperature adapter of PA up to 150°C, from
100°C unpressurized
9
VEGACAP 82, 82 R ExS: unpressurized
VEGACAP 92: up to 6 bar
0
-20
100
150 ˚C
bar
6
Temperature
adapter
1)
11
PP
PTFE
0
-20
80 ˚C
40
bar
60
10
with separate
housing
StSt: up to -50°C
Steel: up to -10°C
Instruments with StEx approval
Mechanical connection, steel (St 37) or
1.4571 (StSt)
Isolation
VEGACAP
11 R ExS
10
9
31 R ExS
10
9
82 R ExS unpressurized
-
9
Ceramic
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)