5.6 Failure rectification

Failure

Measure, failure rectification

No function or

Make sure with Ex-systems that the Ex-protection is not influenced by

defective switching

the meas. instruments.

function

Check the following possible causes of failure:

- shortcircuit
- sensor not correctly connected
- sensor line interrupted
- supply voltage too low

Push the A/B-switch on the oscillator. The relay output of VEGACAP
switches and the control lamp (LED) changes condition. If the relay
output does not switch, the sensor, or rather the oscillator, is defective.

C

T

- Test capacitor

C

M

- Meas. capacitor

C

K

- Compensation capacitor

Screen

Reed
contact

Diagnostics

CAP E30 R