beautypg.com

Experiment 2: adjustable ac voltage – Velleman projects EDU06 Assembly instructions User Manual

Page 7

background image

7

Experiment 2: Adjustable AC voltage

(advantages of the auto-setup function)

Connection layout:

Connection summary:

GND clip : 2
Probe tip : 3

Purpose:

The purpose of this experiment is to show the advantages of the auto-setup function to measure AC
voltage.

How?:

Turn on the HPS140 Handheld Pocket Scope

1.

(see HPS140 manual for How-To instructions).

Place the probe switch “x1/x10” to ‘x1’.

2.

Trimmer RV1 allows us to adjust the output voltage on test
point 3 between 0V and the full input voltage. Turn RV1 fully
anti-clockwise (0V output). The trace on our oscilloscope
screen remains a fl at line, as there is no input voltage.

Next, set V/div to 50mV/div

(see HPS140 manual for How-To instructions).

Slightly turn RV1 clockwise until a sine wave is displayed on
the screen. You only need to turn it slightly before the signal
appears. If the signal goes ‘off-screen’, turn RV1 anti-clock-
wise until the signal is correctly displayed. In the lower right
hand corner, you can read the current RMS value of the AC
voltage measured, e.g. 100mV (0.1V)

y

Connection summary:

:

GND clip : 2
Probe tip : 3

Exp.2: Adjustable AC voltage

(advantages of the auto-setup function)

NOTES:

N

This manual is related to the following products: