144 ah, Charging, Chargers – Power-Sonic PG-12V140 User Manual
Page 2: Further information, Constant current & power discharge ratings, Hr. rate, Contact information

Charging
Cycle Applications: Limit initial current to 25.0A. Charge until battery voltage
(under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7
volts until current drops to under 1.44A. Battery is fully charged under these
conditions, and charger should be disconnected or switched to “float” voltage.
“Float” or “Stand-By” Service: Hold battery across constant voltage source of
13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its
own current level and maintain itself in a fully charged condition.
Note: Due to the self-discharge characteristics of this type of battery, it is
imperative that they be charged within 6 months of storage, otherwise permanent
loss of capacity might occur as a result of sulfation.
Chargers
Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH.
Please refer to the Charger Selection Guide in our specification sheets for “C-Series
Switch Mode Chargers” and “Transformer Type A and F Series”. Please contact our
Technical department for advice if you have difficulty in locating suitable models.
®
Further Information
Please refer to our website www.power-sonic.com for a complete range of useful
downloads, such as product catalogs, material safety data sheets (MSDS), ISO
certification, etc..
Constant Current & Power Discharge Ratings
MODEL
FINAL
VOLTAGE
AMPS/WATTS PER CELL @ 25° C
5 MIN
10 MIN
15 MIN
20 MIN
30 MIN
45 MIN
60 MIN
A
W
A
W
A
W
A
W
A
W
A
W
A
W
PG-12V140 FR
1.80
270
604
231
490
200
410
177
342
144
286
104
208
84
165
1.75
309
628
252
532
219
435
195
378
154
303 113.5 214
84.9
167
1.67
354
654
289
568
252
478
213
385
163
306
113
218
84
168
1.60
440
675
319
625
260
486
214
396
161
309
112
223
85.7
170
C
ap
ac
ity
R
et
en
tion
R
at
io
(%
)
Standing Period (Months)
100
80
60
40
0
0 2 4 6 8 10 12 14 16 18 20
40
o
C
(104
o
F)
30
o
C
(86
o
F)
20
o
C
(68
o
F)
5
o
C
(41
o
F)
Charging is not
necessary unless
100% of capacity
is required.
Charging before
use is necessary
to help recover
full capacity.
Chargemayfail
to restore full
capacity. Do not
let batteries reach
this state.
Discharge Characteristics
Discharge Time vs. Discharge Current
Shelf Life & Storage
Discharge Current (A)
Discharge T
ime
Discharge Time
Terminal V
oltage (V)
Ambient Temperature: 25°C(77°F)
10
9
8
7
6
5
4
3
60
50
40
30
20
10
8
6
4
7 8 9 13 14.4 18 20 40 60 92 144 310
0
(min
)
(h
)
460 820
2
40°C (104°F)
25°C ( 77°F)
0°C ( 32°F)
13
12
11
10.8
10.5
9.6
9
7.8
3
5 10
20
30
0
2 3
5
10
20
(min)
(h)
84A
36.4A 24.1A
14.4A 7.7A
140A
60
PG-12V140
FR
12 Volt 154 AH
@ 20-hr. rate
, 144 AH
@ 10-hr. rate
CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650
CUSTOMER SERVICE
Tel: +1-619-661-2030
Fax: +1-619-661-3648
INTERNATIONAL SALES
Tel: +1-650-364-5001
Fax: +1-650-366-3662
DOMESTIC SALES
Tel: +1-619-661-2020
Fax: +1-619-661-3650
TECHNICAL SUPPORT
Tel: +1-619-661-2020
Fax: +1-619-661-3648
Contact Information
www.power-sonic.com
0111 1M