Power-Sonic PS-1212 User Manual
Ps range, 5yr design life in float service at 20 c) º
PS Range
Discharge Characteristics (25ºC, 77ºF)
Physical Specification
Internal Resistance mΩ
Dimensions (mm)
Standard terminal (mm)
Power-Sonic Europe Limited
3 Buckingham Square, Wickford, Essex, SS11 8YQ
Tel: +44 (0)1268 560686 Fax: +44 (0)1268 560902
www.power-sonic.co.uk
PS-1212 12V 1.2AH
Nominal Voltage
Nominal Capacity (20HR)
12V
1.2 AH
Dimension
Length
Width
Container Height
Total Height (with terminal)
Weight
Standard Terminal
F1
Approx 0.57kg
97
43
52
58
2 mm
2 mm
2 mm
2 mm
+
-
+
-
+
+
-
Rated
Capacity
Capacity
Affected by
Temperature
Cycle
Standby
C
o
n
s
ta
n
t
V
o
lt
a
g
e
C
h
a
rg
e
Initial Charging Current
Less than 0.3A
Voltage 14.40V ~ 15.0V
at 25°C (77°F)
Recommended Charge
Current less than 0.3A
Voltage 13.5V ~
13.8V at 25°C (77°F)
40°C (104°F)
25°C (77°F)
0°C (32°F)
103%
100%
86%
4.75
6.35
3.2
0.8
F1
Rev4 04-13
+
-
5
2
2
5
8
2
43 2
97 2
90.0 mΩ
-
(5yr Design Life in Float Service at 20 C)
º
In the event of further technical development we reserve the right to alter our design, specification and price without notice. E&O.E
20hRate(1.80V/cell) 1.20AH
10hRate(1.80V/cell) 1.12AH
5hRate(1.75V/cell) 1.02AH
3hRate(1.75V/cell) 0.92AH
1hRate(1.60V/cell) 0.75AH
F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
2.29
1.75
1.45
1.26
0.97
0.716
0.603
0.357
0.279
0.227
0.185
0.161
0.130
0.108
0.0594
1.80V/cell
3.07
2.24
1.76
1.49
1.15
0.833
0.676
0.390
0.300
0.242
0.199
0.172
0.137
0.112
0.0600
1.75V/cell
3.46
2.46
1.92
1.60
1.19
0.864
0.707
0.404
0.306
0.248
0.204
0.177
0.140
0.115
0.0606
1.70V/cell
3.81
2.69
2.05
1.68
1.24
0.899
0.729
0.414
0.315
0.254
0.209
0.181
0.142
0.117
0.0617
1.65V/cell
4.20
2.90
2.18
1.78
1.31
0.921
0.746
0.420
0.328
0.263
0.215
0.185
0.144
0.119
0.0625
1.60V/cell
4.63
3.15
2.33
1.90
1.38
0.960
0.754
0.438
0.338
0.271
0.222
0.189
0.145
0.121
0.0629
Constant Current Discharge (Amperes) at 25°C (77°F)
F.V/Time
5min
10min
15min
20min
30min
45min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V/cell
4.18
3.24
2.71
2.37
1.85
1.38
1.16
0.693
0.544
0.444
0.363
0.316
0.256
0.214
0.118
1.80V/cell
5.55
4.09
3.23
2.76
2.15
1.59
1.30
0.751
0.582
0.471
0.388
0.337
0.271
0.221
0.119
1.75V/cell
6.12
4.43
3.49
2.94
2.22
1.63
1.35
0.776
0.591
0.480
0.397
0.346
0.275
0.226
0.120
1.70V/cell
6.56
4.71
3.67
3.07
2.29
1.69
1.39
0.794
0.606
0.492
0.406
0.352
0.278
0.231
0.122
1.65V/cell
7.13
5.04
3.87
3.23
2.40
1.72
1.41
0.801
0.629
0.507
0.416
0.359
0.282
0.235
0.123
1.60V/cell
7.68
5.35
4.08
3.41
2.52
1.78
1.42
0.831
0.645
0.521
0.428
0.365
0.284
0.237
0.124
Constant Power Discharge (Watts/cell) at 25°C (77°F)