beautypg.com

Power-Sonic PG-12v5.4 User Manual

Pg range, Pg12v5.4, 6yr design life in float service at 20 º c)

background image

PG Range

Discharge Characteristics (25ºC, 77ºF)

Physical Specification

Internal Resistance mΩ

Dimensions (mm)

Standard terminal (mm)

Power-Sonic Europe Limited

3 Buckingham Square, Wickford, Essex, SS11 8YQ

Tel: +44 (0)1268 560686 Fax: +44 (0)1268 560902

[email protected]

www.power-sonic.co.uk

PG12V5.4

Nominal Voltage

Nominal Capacity

12V

5.4 AH

Dimension

Length

Width

Container Height

Total Height (with terminal)

Weight

Standard Terminal

F1/F2 (standard)

151

51

92

97

2 mm

2 mm

2 mm

2 mm

+

-

+

-

+

+

-

Rated

Capacity

Capacity

Affected by

Temperature

20hr Rate(1.80V/cell)
10hr Rate(

)

1.80V/cell

8hr Rate(

)

1.75V/cell

5hr Rate(

)

1.75V/cell

1hr Rate(

)

1.60V/cell

5.40AH
5.19AH
5.11AH
4.78AH
4.14AH

Cycle

Standby

C

on

st

ant

V

ol

ta

g

e

C

harg

e

Initial Charging Current
Less than 1.35A
Voltage 14.4V ~ 15.0V
at 25°C (77°F)

Recommended Charge
Current less than 1.35A
Voltage 13.5V ~
13.8V at 15°C (77°F)

40°C (104°F)

25°C (77°F)

0°C (32°F)

103%

100%

86%

F1 (F2)

4.75(6.35)

6.35(7.95)

3.2 (3.4)

0.8

92

2

97

2

+

-

151 2

31

2

51 2

35.0 mΩ

Rev2 03/12

F2

F1

Approx 1.98kg

(6yr Design Life in Float Service at 20ºC)

F.V/Time

5mn

10mn

15mn

20mn

30mn

45mn

1H

2H

3H

4H

5H

6H

7H

8H

9H

10H

20H

1.90V

11.6

9.0

7.12

6.02

4.68

3.59

3.12

1.76

1.27

0.99

0.820

0.700

0.630

0.560

0.510

0.480

0.244

1.85V

14.4

10.5

8.17

6.70

5.04

3.79

3.30

1.85

1.33

1.05

0.866

0.739

0.658

0.590

0.540

0.500

0.258

1.80V

17.8

12.2

9.22

7.46

5.67

4.18

3.50

1.98

1.41

1.10

0.920

0.784

0.696

0.618

0.562

0.519

0.270

1.75V

20.1

13.5

10.10

8.09

5.98

4.36

3.63

2.05

1.48

1.17

0.955

0.820

0.725

0.639

0.576

0.533

1.70V

21.4

14.3

10.50

8.45

6.26

4.59

3.80

2.12

1.52

1.19

0.983

0.852

0.753

0.668

0.597

0.547

1.65V

23.0

14.9

11.10

9.04

6.53

4.87

3.97

2.21

1.57

1.23

1.020

0.877

0.774

0.682

0.611

0.561

1.60V

25.1

15.9

11.90

9.66

7.02

5.10

4.14

2.27

1.61

1.26

1.040

0.896

0.788

0.699

0.628

0.576

F.V/Time

5mn

10mn

15mn

20mn

30mn

45mn

1H

2H

3H

4H

5H

6H

7H

8H

9H

10H

20H

1.90V

22.80

17.92

14.20

12.08

9.45

7.28

6.35

3.58

2.60

2.03

1.69

1.44

1.30

1.16

1.05

0.99

0.51

1.85V

27.63

20.35

16.00

13.25

10.08

7.63

6.70

3.77

2.72

2.15

1.78

1.52

1.36

1.22

1.12

1.03

0.53

1.80V

33.63

23.25

17.72

14.47

11.10

8.28

7.00

3.98

2.85

2.23

1.87

1.60

1.43

1.27

1.15

1.07

0.56

1.75V

37.17

25.32

19.18

15.53

11.62

8.60

7.23

4.12

2.98

2.37

1.93

1.67

1.48

1.31

1.18

1.10

1.70V

38.50

26.23

19.67

16.12

12.10

9.02

7.55

4.23

3.07

2.40

2.00

1.73

1.54

1.36

1.23

1.12

1.65V

40.80

27.08

20.63

17.10

12.52

9.48

7.83

4.38

3.15

2.47

2.07

1.78

1.57

1.39

1.26

1.15

1.60V

43.52

28.25

21.75

18.08

13.37

9.88

8.12

4.48

3.20

2.53

2.10

1.82

1.60

1.42

1.29

1.18

Constant Current Discharge Characteristics Unit: Amperes (

)

25ºC, 77ºF

Constant Power Discharge Characteristics Unit: (Watts/cell) (

)

25ºC, 77ºF

In the event of further technical development we reserve the right to alter our design, specification and price without notice. E&O.E

Table of contents