Cycle Applications: Limit initial current to 25.0A. Charge until battery voltage
(under charge) reaches 14.4 to 14.7 volts at 68°F (20°C). Hold at 14.4 to 14.7
volts until current drops to under 1.24A. Battery is fully charged under these
conditions, and charger should be disconnected or switched to “float” voltage.
“Float” or “Stand-By” Service: Hold battery across constant voltage source of
13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its
own current level and maintain itself in a fully charged condition.
Note: Due to the self-discharge characteristics of this type of battery, it is
imperative that they be charged within 6 months of storage, otherwise permanent
loss of capacity might occur as a result of sulfation.
Chargers
Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH.
Please refer to the Charger Selection Guide in our specification sheets for “C-Series
Switch Mode Chargers” and “Transformer Type A and F Series”. Please contact our
Technical department for advice if you have difficulty in locating suitable models.
®
Further Information
Please refer to our website www.power-sonic.com for a complete range of useful
downloads, such as product catalogs, material safety data sheets (MSDS), ISO
certification, etc..
Constant Current & Power Discharge Ratings
MODEL
FINAL
VOLTAGE
AMPS/WATTS PER CELL @ 25° C
5 MIN
10 MIN
15 MIN
20 MIN
30 MIN
45 MIN
60 MIN
A
W
A
W
A
W
A
W
A
W
A
W
A
W
PG-12V120 FR
1.80
232
598
198
485
172
394
152
330
124
242
90
176
72
143
1.75
265
620
216
510
188
412
167
341
132
258
130
182
72.5
144
1.67
304
635
248
538
216
430
182
352
140
263
96.7
192
74.4
145
1.60
377
658
274
562
224
442
183
360
143
269
99
197
73.5
147
C
ap
ac
ity
R
et
en
tion
R
at
io
(%
)
Standing Period (Months)
100
80
60
40
0
0 2 4 6 8 10 12 14 16 18 20
40
o
C
(104
o
F)
30
o
C
(86
o
F)
20
o
C
(68
o
F)
5
o
C
(41
o
F)
Charging is not
necessary unless
100% of capacity
is required.
Charging before
use is necessary
to help recover
full capacity.
Chargemayfail
to restore full
capacity. Do not
let batteries reach
this state.
Discharge Characteristics
Discharge Time vs. Discharge Current
Shelf Life & Storage
Discharge Current (A)
Discharge T
ime
Discharge Time
Terminal V
oltage (V)
10
9
8
7
6
5
4
3
60
50
40
30
20
10
8
6
4
2 5 7 11
12 14 17 30 50 70 120 240
0
(min
)
(h
)
360 600
2
40°C (104°F)
25°C ( 77°F)
0°C ( 32°F)
Ambient Temperature: 25°C(77°F)
13
12
11
10.8
10.5
9.6
9
7.8
3
5 10
20
30
0
2 3
5
10
20
(min)
(h)
74.4A
32A 21.3A
12.4A 6.48A
120A
60
PG-12V120
FR
12 Volt 129 AH
@ 20-hr. rate
, 124 AH
@ 10-hr. rate
CORPORATE OFFICE • 7550 Panasonic Way • San Diego, CA 92154 • USA • Tel: +1-619-661-2020 • Fax: +1-619-661-3650
CUSTOMER SERVICE
Tel: +1-619-661-2030
Fax: +1-619-661-3648
INTERNATIONAL SALES
Tel: +1-650-364-5001
Fax: +1-650-366-3662
DOMESTIC SALES
Tel: +1-619-661-2020
Fax: +1-619-661-3650
TECHNICAL SUPPORT
Tel: +1-619-661-2020
Fax: +1-619-661-3648
Contact Information
www.power-sonic.com
0111 1M
© 2011. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.