beautypg.com

Ohaus DEFENDER 5000 BENCH SCALES Manual en User Manual

Page 37

background image

EN-35

5000 Series Indicators

Line Feed
Set the paper feed.
LINE = move paper up one line after printing
4.LINE = move paper up four lines after printing
FOrM = a form feed is appended to the printout

3.9.6 Output

Set the format of the serial output string to a printer or computer.

DEF = use the default output format of the T51 indicator (see Section 5.2 Output Format).
C11 = use the output format of the Ohaus CD/CW-11 indicators (see respective
CD-11/CW-11 user manuals).

3.9.7 List Menu Settings

Print the menu settings.
NO = do not print.
YES = print.

3.9.8 End Print1 or End Print2

Advance to the next menu.

3.9.5 Layout Sub-menu

This sub-menu is used to define format of data output to a printer or computer.

Format
Set the printing format.
MULtI = a multi-line (single column style) printout is generated. A CRLF is added after each
item.
SINGLE = a single line printout is generated. (A TAB space is added between each item and a
CLRF is used only after the very last item.)

3.10 COM1 and COM2 Menus

The table shows the items in the communication menus. Default settings are

bold.

Enter the menu to define communication parameters.

Reset

No, Yes

Baud Rate 300, 600, 1200, 2400, 4800,

9600, 19200

Parity 7 Even, 7 Odd, 7 None,

8 None

Stop Bit

1, 2

Handshake

None, XON/XOFF, Hardware

Address

Off, 01,…, 99

Alt Command Print (->

Off, A … P … Z), Tare (-> Off, A … T … Z),

Zero (->

Off, A … Z)

End Com1 Exit COM1 menu
(End Com2) Exit COM2 menu

NOTE: The COM2 menu is only displayed if a
second interface (RS232 or RS422/RS485) is
installed.